Contact Getein
Products
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-480 Clinical Chemistry Analyzer
    Key Features High-Efficiency Sample Processing  Optional ISE module: 600 T/H 105 cuvettes: quartz glass or plastic Whole Blood Testing-HbA1c Direct testing with whole blood samples; automatic on-board hemolysis and analysis No manual pre-treatment required, ensuring higher accuracy  Simplified operation and improved testing efficiency IFCC and NGSP standardization Air Bath Heating System Constant-temperature air bath with rapid heating reduces instrument warm-up time and requires no maintenance The temperature control system utilizes dry heating to maintain the reaction solution in the cuvette at 37 ℃ Compact and Connectable Integrated with the MAGICL 6000i to form the Metis 600, the smallest clinical chemistry and immunochemistry modular system on the market—maximizing space savings while also shortening turnaround time 8-Step Warm Liquid Washing Cross-contamination rate < 0.01% Water consumption: 15 L/H and 2-step washing solution + 4-step purified water washing Intelligent 3D full-needle washing technology and ultrasonic cleaning system Automatic wash solution dilution Accurate Sampling System Minimum reaction volume: 100 μL Highly-precise injector, internally and externally polished sampling probes, liquid level detection and bubble detection Advanced Optical System LED light source with high stability, long lifespan optical system with diffraction grating and 16 wavelengths Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 960 mm (L) * 770 mm (W) * 655 mm (H) Sample Positions: 50 positions  Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 15 L purified water per hour Minimum Reaction Volume: 100μL  
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    DC 3100 Dry Clinical Chemistry Analyzer
    Key Features Intelligent Sampling System Constant throughput with built-in ISE 400 T/H Automatic decapping and recapping Automated sample system with probe clogging detection, liquid level monitoring Multilayered Dry Chemistry Technology Dry chemistry system reduces HIL interference for more accurate results, shortens sample turnaround time and uses no water Compact and Connectable Small footprint only takes up 0.42 ㎡ and offers flexible installation with plug-and-play operation  Connectable with MAGlCL 6000 to form the Metis 600⸺One tube of whole blood sample to test, also connectable with Getein 1200 which enables liquid-free testing Advanced Optical System A durable LED light source ensures 60000 hours long lifespan, stable illumination, and low maintenance cost Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles:Colorimetry; Direct ISE method Dimensions: 628 mm (L) * 671 mm (W) * 810 mm (H) Sample Positions: 50  Sample Type:Whole blood/Serum/Plasma/Urine Minimum Sample Volume: 10 μL per test Reagent Positions: 40 Light Source: LED    
  • Compact Blood Coagulation Analyzer
    Compact Blood Coagulation Analyzer
    CA-5700 Automated Coagulation Analyzer
    Key Features Faster Report Time From an inactive state to the first result takes only 3 minutes Intuitive Indicator The indicator lights will give reminding of reagents & cleaning solution insufficiency and waste area brim More Cost-effective  Tilted aspirating of reagents to reduce dead space volume  More Precise The reagent/sample probes demonstrate high precision Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Techinical Specifications Methodology: Clot, chromogenic and immunoturbidimetric principles Throughput: 400 T/H Analysis Wavelengths: 405 nm, 575 nm, 660 nm, 800 nm Reagent Positions: 190 Reagent Positions: 40 tilted reagent positions (refrigerated), 5 tilted dilution positions (room temperature) Storage Capacity: 100,000 reaction curves Operation: 21.5-inch touch all-in-one + Windows operating system Dimensions: 1670 mm x 922 mm x 1310 mm (L x W x H)  Weight: 450 kg  
  • Automatic Clinical Chemistry Analyzer
    Automatic Clinical Chemistry Analyzer
    CM-50 Vet Automatic Clinical Chemistry Analyzer
    Key Features Easy and Quick Simple operation: add sample → perform the test → get result in 12 min Micro Blood Collection 100 μL microvolume sampling, small animals friendly Multiple Packages A variety of check-up packages:one sample, multiple indicators Compact Appearance Portable and compact appearance, meet the needs of animal hospitals Accurate Results With professional intelligent quality control system to guarantee the accuracy of results Test Menu Techinical Specifications Test Principles: Absorption spectrophotometry Sample Volume: 100 µL Sample Types: Whole blood, serum, plasma Languages: Chinese, English Screen Size: 7-inch android screen, 1024 mm * 600 mm resolution Printer: Built-in thermal printer, supports Wi-Fi data transmission for printing A4 reports on Ani-Q Power Supply: 100-240 VAC, 50 Hz~60 Hz; Input Power: 200 VA    
  • 3-part Veterinary Automatic Hematology Analyzer
    3-part Veterinary Automatic Hematology Analyzer
    BHA-3000 Vet Automatic Hematology Analyzer
    Key Features Fast Test Utilizing double-channel test mode No Residue No residue of hematology diluent or lysing reagent;Cost effective Easy and Convenient Operation Large LCD touch screen High-definition color monitor, no need of external computer Built-in printer to fast print test results Supports Wi-Fi data transmission for printing A4 reports on Ani-Q Optimized Liquid System Very low failure rate & excellent maintainability Intelligent Floating Threshold Making the classification more accurate Techinical Specifications 19 Reportable Parameters: WBC, NEU#, MXD#, LYM#, NEU%, MXD%, LYM%, RBC, HGB, MCV, RDW-CV, MCHC, MCH, RDW-SD, HCT, PLT, MPV, PDW, PCT Principles: Classic Electrical Impedance Method, Mature Photoelectric Colorimetry Sample Mode: Whole Blood Sample Volume: Venous blood: 10 μL QC Methods: L-J QC, X-B QC Data Storage: 10000 Screen Type: 10.4 inch Resistive Screen Power Supply: 100-240 V~ 50/60 Hz Weight: 16 kg Dimension: 328 mm x 425 mm x 446 mm (L x W x H) Operating Conditions: 18~30℃, ≤80% Relative Humidity, 75 kPa~106 kPa  
  • Compact Blood Coagulation Analyzer
    Compact Blood Coagulation Analyzer
    CA-5500 Automated Coagulation Analyzer
    Key Features HIL interference warning The fully automated HIL sample solution provides superior resistance to sample interference Temperature Control Sample incubation module and reagent refrigeration system, ensuring exceptional accuracy of results STAT  The STAT function prioritizes emergency samples, ensuring they are processed immediately  Tilted Aspirating Design Reduce dead space volume of reagent Application Scenarios Medical Laboratories  Clinics Health Check-up Center Test Menu Techinical Specifications Methodology: Clot, chromogenic and immunoturbidimetric principles Throughput: 200 T/H Sample Positions: 20 Reagent Positions: 20 Storage Capacity: 100,000 reaction curves Operation: 10.1 inches high-definition touch screen Dimensions: 518 mm x 495 mm x 545 mm (L x W x H)  Weight: 40 kg Reagent Cabin: 14.0 ℃ ± 1.0 ℃ Incubation Area: 37.0 ℃ ± 1.0 ℃  Reagent Probe: 37.0 ℃ ± 1.0 ℃  Testing Area: 37.0 ℃ ± 1.0 ℃  
  • Blood Testing Device
    Blood Testing Device
    BHA-3000 Automatic Hematology Analyzer
    Key Features No Residue No residue of hematology diluent or lysing reagent Cost-effective Small Blood Sample Venous blood: 6 μL Capillary blood (pre-dilution mode): 20 μL Intelligent Floating Threshold Accurate classification & reliable result Optimized Liquid System Limited failure rate & excellent maintainability Linear Fitting Break the 2 fL limit of detection of platelet volume Reportable Parameters WBC, NEU#, MXD#, LYM#, NEU%, MXD%, LYM%, RBC, HGB, MCV, RDW-CV, MCHC, MCH, RDW-SD, HCT, PLT, MPV, PDW, PCT, P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 6 μL; capillary blood (pre-dilution): 20 μL Principles: Classic electrical impedance method, photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 328 mm x 425 mm x 446 mm (L x W x H)  Weight:16 kg Power Supply: 220V~ 50 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • Blood Testing Device
    Blood Testing Device
    BHA-5000 Automatic Hematology Analyzer
    Key Features Digital Filtering Effectively remove interference Small Blood Sample Venous blood: 15 μL Capillary blood (pre-dilution mode): 20 μL Double Channels WBC double channels 2D classification, faster and more accurate 50μm Hole Accurate test of blood cells with 50 μm gem hole Coincidence Calibration Enhance analytical capabilities Reportable Parameters WBC, LYM#, NEU#, MON#, EOS#, BAS#, LYM%, MON%, NEU%, EOS%, BAS%,  RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: White blood cell: laser scattering + sheath flow technology; red blood cell/platelet: impedance method; hemoglobin: photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 328 mm x 471 mm x 446 mm (L x W x H)  Weight: 21 kg Power Supply: 100-240 V~ 50/60 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • 5-part Veterinary Automatic Hematology Analyzer
    5-part Veterinary Automatic Hematology Analyzer
    BHA-5000 Vet Automatic Hematology Analyzer
    Key Features Principles Laser scatter in flow cytometry Classic electrical impedance method Mature photoelectric colorimetry Fast Test Use double-channel test mode with 60 T/H More Accurate Test Use optical method to detect Basophil Curve fitting, floating threshold technology lntelligent scatter classification technology The smallest gem hole in the industry with high sensitivity Digital filtering, coincidence correction in blood cell counting Optical Method for BASO: Avoid errors caused by the partial Technical Specifications 23 Reportable Parameters:RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, WBC, NEU (#), LYM (#), MON (#), EOS (#), BAS (#), NEU (%), LYM (%), MON (%), EOS (%), BAS (%), PLT, MPV, PDW, PCT Analysis Speed: 60 T/H Screen Size: 10.1-inch touch screen Whole Blood Sample Volume: 30 μL Supported Languages: Chinese, English, Russian, Spanish Printer: Built-in thermal printer, supports WiFi data transmission   Supported Species: Cat, dog, and one user-defined animal species Detection Principles: Laser flow cytometry, photoelectric colorimetry 50 μm Gem Aperture: Ensures precise Red Blood Cell (RBC) detection  
  • Automatic 5-part Hematology Analyzer
    Automatic 5-part Hematology Analyzer
    BHA-5100 Automatic Hematology Analyzer
    Key Features Advanced Automatic Level Autorotating blood collection tubes for barcode scanning Automatic sample mixing technology Automatic puncture sampling Exceeding Detection Technology Digital filter and linear regression Floating threshold technology for cell differentiation Display Screen ≥10.4 inch LCD display screen Able to display data and diagrams simultaneously User Friendly Minimize manual operations Bidirectional connectivity of LIS and HIS Supports external devices such as printers, keyboards, mouse and more Emergency Sample Position Available   Reportable Parameters WBC, Lym#, Neu#, Mon#, Eos#, Bas#, Lym%, Mon%, Neu%, Eos%, Bas%,  RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT,  P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: White blood cell: laser scattering + sheath flow technology; red blood cell/platelet: impedance method; hemoglobin: photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 705 mm×670 mm×570 mm (L x W x H) Weight: 30 kg Power Supply: 100-240 V~ 50/60 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • Compact POC PCR Analyzer
    Compact POC PCR Analyzer
    GN 7000 Akso PCR System
    Key Features Sample In - Result Out Compact design &All-in-One system Fully automated nucleic acid extraction→PCR amplification→detection→analysis Quick Test Fastest turnaround time of 35 min from sample to result High Throughput Dual-module design, 4 test channels Multiple items could be detected simultaneously Room Temperature Transportation & Storage Advanced technology, freeze-dried reagent Convenient and cost- effective transportation Applicable Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Real-time PCR Time for the Result: 35 min Channels: 4 Module Number: 2 Sample Type: Nasopharyngeal swab, conjunctiva swab, anal swab, feces, whole blood, serum, oral and nasal secretion, genital tract swab, urinary tract swab, lesion exudate, cervical swab, sputum Thermal Cycling Technology: Peltier Dimensions: 419mm(L)*310 mm(W)*233 mm(H) Weight: 9.5 kg  
1 2 3 ... 8