RF Fast Test Kit (Immunofluorescence Assay) Intended Use RF Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of rheumatoid factor (RF) in serum, plasma or whole blood samples. The test is designed to aid in the diagnosis of autoimmune diseases, such as rheumatoid arthritis (RA). About RF Rheumatoid factor is an autoantibody targeting the Fc fragment of human or animal denatured IgG molecule. RF mainly includes four types of IgM, IgG, IgA and IgE. IgM is the main type of RF, and this test kit mainly detects this type. Specification Test Item Sample Type Method Storage Condition RF S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 10.0-640.0 IU/mL 10 min 15.9 IU/mL 24 months Applicable Device Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer
Cardiopulmonary Rehabilitation can improve cardiac and systemic dysfunction caused by cardiovascular diseases, solve residual disease problems after acute and severe diseases, prevent recurrence of cardiovascular events, and help patients return to a healthy life.
Key Features Better Cost-effectiveness One stirrer less — Upgraded mechanics with reduced maintenance High-effciency Sample Processing Constant throughput: 400 T/H, optional ISE module with 400 T/H 90 sample positions, 80 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Bubble detection and probe-clot (clogging) detection Water-quality monitoring module (Optional) and Built-in degassing unit Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use Intelligent Online Loading System Reagents can be loaded on-board during test Peltier system provides a longer maintenance period to reduce repair probability 8-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1160 mm (L) * 790 mm (W) * 1140 mm (H) Gross Weight: 300 kg Sample Positions: 90 positions Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes Water Consumption: No more than 15 L purified water per hour Calibration: multi-point calibration curve with up to 7 points Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL
Key Features Sample In - Result Out Compact design &All-in-One system Fully automated nucleic acid extraction→PCR amplification→detection→analysis Quick Test Fastest turnaround time of 35 min from sample to result High Throughput Dual-module design, 12 test channels Multiple items could be detected simultaneously Room Temperature Transportation & Storage Advanced technology, freeze-dried reagent Convenient and cost- effective transportation Applicable Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Real-time PCR Time for the Result: 35 min Channels: 12 Module Number: 2 Sample Type: Nasopharyngeal swab, conjunctiva swab, anal swab, feces, whole blood, serum, oral and nasal secretion, genital tract swab, urinary tract swab, lesion exudate, cervical swab, sputum Thermal Cycling Technology: Peltier Dimensions: 424mm(L)*420 mm(W)*234 mm(H) Weight: 13 kg
Key Features Compact Design Bench top design Relatively lighter weight: 80 kg High Efficiency Throughput: up to 200 T/HFastest time for the first result: 10 min Dual-Tray Consumable Design 2 independent consumable trays, support replacement without pause 140 reaction cups per tray Smooth Reagent Management 24 reagent positions, support online loading PE film puncture technology, preventing reagents from evaporationEquipped with RFID, automatic identification of reagent information Application Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 200 T/H Fastest Time for the First Result: 10 min Reagent Positions: 24 Sample Positions: 50 Sample Type: Serum, plasma, urine, fingertip blood Application Scenarios: Laboratory, Clinics, Emergency, ICU, Wards Sampling Method: Steel needle STAT: Support STAT mode Sensing Functions: Liquid level detection, residual monitoring of reagent and sample, anti-collision Reaction Cups: 2 individuals consumble trays with 140 reaction cups each Reaction Temperature: 37℃±0.5℃ Magnetic Seperation & Washing: 3-step magnetic separation and 3-step washing Dimensions: 685 mm(L)*690 mm(W)*660 mm(H) Weight: 80 kg
Key Features Maximizing the potential of the laboratory Metis 600 modular system provides suitable solutions for immunofluorescence and hematology testing in low volume laboratories Standardization Improve laboratory efficiency through the highest level of automation Reliability Maximize reliable results with industry-leading instrument accuracy and service Rapid Accelerate turnaround time for high-volume sample testing and achieve new levels of rapid service Capacity The combination of Immunofluorescence and Hematology methodologies allows for a more comprehensive test items to be offered Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Technical Specifications BHA-5100 Automatic Hematology Analyzer Dimensions: 705 mm (L) x 670 mm (W) x 570 mm (H) Weight: 21 kg Methodology: Flow cytometry, impedance method, colorimetry Throughput: 60 T/H Test Items: 25 reportable parameters Quality Control Method: L-J quality control, X-B quality control Storage Capacity: > 100, 000 patient data Gem Hole: 50 μm Sample Volume: 15 μL Reagents: 1 diluent and 2 lysers Getein 1200 Immunofluorescence Quantitative Analyzer Dimensions: 570 mm (L) x 675 mm (W) x 574 mm (H) Weight: 43 kg Methodology: Quantitative immunofluorescence Sample Positions: 50, continuous sample loading Reagent Positions: 4 x 24/48 Throughput: 100 T/H Test Items: 59 items in 13 fields Storage Capacity: 100, 000 test results Dry System: ADP aspiration, no liquid path Automation: Automatic sample loading, mixing and decapping
Key Features High-effciency Sample Processing Constant throughput: 800 T/H, optional ISE module with 400 T/H 137 samples positions, 114 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ High-efficiency Triple Mix Bars Triple mix bars with two-stage cleaning, avoiding stirring rod contamination Real-time monitoring of stirring speed Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Intelligent Online Loading System Reagents can be loaded on-board during test 9-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use (optional) Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1640 mm (L) * 940 mm (W) * 1215 mm (H) Gross Weight: 500 kg Sample Positions: 137 positions Reagent Positions: 114 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes Water Consumption: No more than 26 L purified water per hour Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL
Key Features Fast And accurate tests with small footprint High throughput at 400 T/H can satisfy needs from different hospitals and laboratories Compact footprint, maximizing space utilization efficiency Flexible expansion for modular system Support expansion of centrifuge and decapper module / analysis modules Flexible combination of 4 analysis modules at most, fulfilling requirements from multiple laboratories High automation level Automatic sample loading and scanning, automatic weight balanced in centrifuge module without manual operation Intelligent software system Support auto-dilution and auto-retests Monitor real-time instrument status, testing status, reagent reserve and consumables status Application Scenarios Medical Laboratories Indipendent Clinical Laboratory Health Check-up Center Test Menu Technical Specifications Methodology: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Test Items: 118 items. Up to 85 items tested simultaneously Test Speed: Up to 400 T/H Fastest Time for the First Result:12 min Sample Volume: 10 uL~150 uL (1 uL increment) Sample Loading:Sample loading by tracks, sample/return/emergency track Maximum Loading capacity: 190 sample positions Reagent Volume: 10 uL~150 uL (0.1 uL increment) Reagent Tray: 30 reagent positions Cooling Function: internal air circulation cooling with a range of 4~8℃ Cuvettes:Using mainstream circular cuvettes, up to 2000 can be stored in hopper at a time Incubation Temperature: 37±0.2°C Preheating Time:<15 min Magnetic Separator Cleaning: Four-step magnetic separation, four-step cleaning Dimensions: 1100 mm (L) x 930 mm (W) x 1200 mm (H)
Getein One Step Test for D-Dimer (Colloidal Gold) is used as an aid in the assessment and exclusion of suspected deep vein thrombosis (DVT) or pulmonary embolism (PE) in the Physical Department or emergency room (ER).
Key Features Intelligent Sample Management Module Compatible with different types of sample tubes Automatic recognition of sample height and tube cap Efficient Track, Emergency in Priority 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority Test Cups and Washing Unit Tilt-pour test cups loading, with a maximum capacity of 2000 Four-step washing for more thorough cleaning Reagent Tray Module 30 reagent positions for simultaneous testing of up to 30 different items RFlD recognition of reagents, dynamic refreshing of reagents status Flexible Expansion Compact footprint Flexible expansion of multiple pre-analytical and clinical chemistry/immunochemistry modules Flexible combination of 4 analytical modules at most Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Techinical Specifications Test Principle: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Throughput: Up to 600 T/H Fastest Time of First Result: 12 min Reaction Cup: Using mainstream circular reaction cup, up to 2000 pieces can be stored at a time Reagent Tray: 30 reagent positions with 2-8 ℃ internal air circulation refrigeration Dimensions: : 1100 mm (L) x 873 mm (W) x 1232 mm (H) Sample Volume: 5 μL~150 μL (1 μL increment) Sample Probe: Probe clog detection, horizontal collision prevention, vertical collision prevention, liquid level detection Reagent Volume: 10 μL~ 150 μL (1 μL increment) Reaction Tray: 183 incubation positions, non-contact vortex mixing Carryover Contamination Rate: < 0.1 PPM Test Cup: Maximum 2000 units Heating Method: Direct solid heating Magnetic Separation Washing Station: 4-step magnetic separation, 4-step washing
RF Fast Test Kit (Immunofluorescence Assay) Intended Use RF Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of rheumatoid factor (RF) in serum, plasma or whole blood samples. The test is designed to aid in the diagnosis of autoimmune diseases, such as rheumatoid arthritis (RA). About RF Rheumatoid factor is an autoantibody targeting the Fc fragment of human or animal denatured IgG molecule. RF mainly includes four types of IgM, IgG, IgA and IgE. IgM is the main type of RF, and this test kit mainly detects this type. Specification Test Item Sample Type Method Storage Condition RF S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 10.0-640.0 IU/mL 10 min 15.9 IU/mL 24 months Applicable Device Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer
Cardiopulmonary Rehabilitation can improve cardiac and systemic dysfunction caused by cardiovascular diseases, solve residual disease problems after acute and severe diseases, prevent recurrence of cardiovascular events, and help patients return to a healthy life.
Key Features Better Cost-effectiveness One stirrer less — Upgraded mechanics with reduced maintenance High-effciency Sample Processing Constant throughput: 400 T/H, optional ISE module with 400 T/H 90 sample positions, 80 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Bubble detection and probe-clot (clogging) detection Water-quality monitoring module (Optional) and Built-in degassing unit Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use Intelligent Online Loading System Reagents can be loaded on-board during test Peltier system provides a longer maintenance period to reduce repair probability 8-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1160 mm (L) * 790 mm (W) * 1140 mm (H) Gross Weight: 300 kg Sample Positions: 90 positions Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes Water Consumption: No more than 15 L purified water per hour Calibration: multi-point calibration curve with up to 7 points Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL
Key Features Sample In - Result Out Compact design &All-in-One system Fully automated nucleic acid extraction→PCR amplification→detection→analysis Quick Test Fastest turnaround time of 35 min from sample to result High Throughput Dual-module design, 12 test channels Multiple items could be detected simultaneously Room Temperature Transportation & Storage Advanced technology, freeze-dried reagent Convenient and cost- effective transportation Applicable Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Real-time PCR Time for the Result: 35 min Channels: 12 Module Number: 2 Sample Type: Nasopharyngeal swab, conjunctiva swab, anal swab, feces, whole blood, serum, oral and nasal secretion, genital tract swab, urinary tract swab, lesion exudate, cervical swab, sputum Thermal Cycling Technology: Peltier Dimensions: 424mm(L)*420 mm(W)*234 mm(H) Weight: 13 kg
Key Features Compact Design Bench top design Relatively lighter weight: 80 kg High Efficiency Throughput: up to 200 T/HFastest time for the first result: 10 min Dual-Tray Consumable Design 2 independent consumable trays, support replacement without pause 140 reaction cups per tray Smooth Reagent Management 24 reagent positions, support online loading PE film puncture technology, preventing reagents from evaporationEquipped with RFID, automatic identification of reagent information Application Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 200 T/H Fastest Time for the First Result: 10 min Reagent Positions: 24 Sample Positions: 50 Sample Type: Serum, plasma, urine, fingertip blood Application Scenarios: Laboratory, Clinics, Emergency, ICU, Wards Sampling Method: Steel needle STAT: Support STAT mode Sensing Functions: Liquid level detection, residual monitoring of reagent and sample, anti-collision Reaction Cups: 2 individuals consumble trays with 140 reaction cups each Reaction Temperature: 37℃±0.5℃ Magnetic Seperation & Washing: 3-step magnetic separation and 3-step washing Dimensions: 685 mm(L)*690 mm(W)*660 mm(H) Weight: 80 kg
Key Features Maximizing the potential of the laboratory Metis 600 modular system provides suitable solutions for immunofluorescence and hematology testing in low volume laboratories Standardization Improve laboratory efficiency through the highest level of automation Reliability Maximize reliable results with industry-leading instrument accuracy and service Rapid Accelerate turnaround time for high-volume sample testing and achieve new levels of rapid service Capacity The combination of Immunofluorescence and Hematology methodologies allows for a more comprehensive test items to be offered Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Technical Specifications BHA-5100 Automatic Hematology Analyzer Dimensions: 705 mm (L) x 670 mm (W) x 570 mm (H) Weight: 21 kg Methodology: Flow cytometry, impedance method, colorimetry Throughput: 60 T/H Test Items: 25 reportable parameters Quality Control Method: L-J quality control, X-B quality control Storage Capacity: > 100, 000 patient data Gem Hole: 50 μm Sample Volume: 15 μL Reagents: 1 diluent and 2 lysers Getein 1200 Immunofluorescence Quantitative Analyzer Dimensions: 570 mm (L) x 675 mm (W) x 574 mm (H) Weight: 43 kg Methodology: Quantitative immunofluorescence Sample Positions: 50, continuous sample loading Reagent Positions: 4 x 24/48 Throughput: 100 T/H Test Items: 59 items in 13 fields Storage Capacity: 100, 000 test results Dry System: ADP aspiration, no liquid path Automation: Automatic sample loading, mixing and decapping
Key Features High-effciency Sample Processing Constant throughput: 800 T/H, optional ISE module with 400 T/H 137 samples positions, 114 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ High-efficiency Triple Mix Bars Triple mix bars with two-stage cleaning, avoiding stirring rod contamination Real-time monitoring of stirring speed Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Intelligent Online Loading System Reagents can be loaded on-board during test 9-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use (optional) Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1640 mm (L) * 940 mm (W) * 1215 mm (H) Gross Weight: 500 kg Sample Positions: 137 positions Reagent Positions: 114 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes Water Consumption: No more than 26 L purified water per hour Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL
Key Features Fast And accurate tests with small footprint High throughput at 400 T/H can satisfy needs from different hospitals and laboratories Compact footprint, maximizing space utilization efficiency Flexible expansion for modular system Support expansion of centrifuge and decapper module / analysis modules Flexible combination of 4 analysis modules at most, fulfilling requirements from multiple laboratories High automation level Automatic sample loading and scanning, automatic weight balanced in centrifuge module without manual operation Intelligent software system Support auto-dilution and auto-retests Monitor real-time instrument status, testing status, reagent reserve and consumables status Application Scenarios Medical Laboratories Indipendent Clinical Laboratory Health Check-up Center Test Menu Technical Specifications Methodology: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Test Items: 118 items. Up to 85 items tested simultaneously Test Speed: Up to 400 T/H Fastest Time for the First Result:12 min Sample Volume: 10 uL~150 uL (1 uL increment) Sample Loading:Sample loading by tracks, sample/return/emergency track Maximum Loading capacity: 190 sample positions Reagent Volume: 10 uL~150 uL (0.1 uL increment) Reagent Tray: 30 reagent positions Cooling Function: internal air circulation cooling with a range of 4~8℃ Cuvettes:Using mainstream circular cuvettes, up to 2000 can be stored in hopper at a time Incubation Temperature: 37±0.2°C Preheating Time:<15 min Magnetic Separator Cleaning: Four-step magnetic separation, four-step cleaning Dimensions: 1100 mm (L) x 930 mm (W) x 1200 mm (H)
Getein One Step Test for D-Dimer (Colloidal Gold) is used as an aid in the assessment and exclusion of suspected deep vein thrombosis (DVT) or pulmonary embolism (PE) in the Physical Department or emergency room (ER).
Key Features Intelligent Sample Management Module Compatible with different types of sample tubes Automatic recognition of sample height and tube cap Efficient Track, Emergency in Priority 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority Test Cups and Washing Unit Tilt-pour test cups loading, with a maximum capacity of 2000 Four-step washing for more thorough cleaning Reagent Tray Module 30 reagent positions for simultaneous testing of up to 30 different items RFlD recognition of reagents, dynamic refreshing of reagents status Flexible Expansion Compact footprint Flexible expansion of multiple pre-analytical and clinical chemistry/immunochemistry modules Flexible combination of 4 analytical modules at most Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Techinical Specifications Test Principle: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Throughput: Up to 600 T/H Fastest Time of First Result: 12 min Reaction Cup: Using mainstream circular reaction cup, up to 2000 pieces can be stored at a time Reagent Tray: 30 reagent positions with 2-8 ℃ internal air circulation refrigeration Dimensions: : 1100 mm (L) x 873 mm (W) x 1232 mm (H) Sample Volume: 5 μL~150 μL (1 μL increment) Sample Probe: Probe clog detection, horizontal collision prevention, vertical collision prevention, liquid level detection Reagent Volume: 10 μL~ 150 μL (1 μL increment) Reaction Tray: 183 incubation positions, non-contact vortex mixing Carryover Contamination Rate: < 0.1 PPM Test Cup: Maximum 2000 units Heating Method: Direct solid heating Magnetic Separation Washing Station: 4-step magnetic separation, 4-step washing