Contact Getein
Products
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-800 Clinical Chemistry Analyzer
    Key Features High-effciency Sample Processing  Constant throughput: 800 T/H, optional ISE module with 400 T/H 137 samples positions, 114 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ High-efficiency Triple Mix Bars Triple mix bars with two-stage cleaning, avoiding stirring rod contamination Real-time monitoring of stirring speed Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Intelligent Online Loading System Reagents can be loaded on-board during test 9-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Advanced Optical system  Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use (optional) Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1640 mm (L) * 940 mm (W) * 1215 mm (H) Gross Weight: 500 kg Sample Positions: 137 positions  Reagent Positions: 114 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 26 L purified water per hour Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL  
  • Single Channel Portable POCT Analyzer
    Single Channel Portable POCT Analyzer
    Getein 1100 Immunofluorescence Quantitative Analyzer
    Key Features Highly Efficient & Accurate Advanced fluorescence immunoassay Multiple quality control Convenient Operation RFID card calibration Continuous test for 3 hours with lithium battery Real-time and Rapid Test 3-15 min/test 5 sec/test for multiple tests User-friendly Interface Android system 7-inch touch screen Application Scenarios ICU Laboratory Emergency Clinic     Test Menu   Technical Specifications Methodology: Fluorescence Immunochromatography Channels: Single channel Sample Types: Serum, plasma, whole blood, urine, feces, fingertip blood, nasal swab, saliva Detection Time: 3-15 minutes Printer: Built-in thermal printer, paper size 5735 mm Display: 7.0-inch LCD color capacitive touchscreen, resolution 1024600, supports touch and handwriting operations Dimensions: 261 mm (L) × 241 mm (W) × 115 mm (H) Net Weight: Main unit 2000g, power adapter 430g, lithium battery pack (optional) 300g Operating System: Android system Data Storage: Stores 10,000 results (reagent storage capacity of 100,000, but excessive storagemay cause the Android system to crash; timely data cleanup is recommended)   Communication Input: One SD card (old) slot, two USB ports Communication Output: One RS232 serial port, one Ethernet port Languages: English, Chinese, Spanish, Portuguese Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV    
  • Chemiluminescence Immunoassay Analyzer
    Chemiluminescence Immunoassay Analyzer
    MAGICL 6200 Chemiluminescence Immunoassay Analyzer
    Key Features Fast And accurate tests with small footprint High throughput at 400 T/H can satisfy needs from different hospitals and laboratories Compact footprint, maximizing space utilization efficiency Flexible expansion for modular system Support expansion of centrifuge and decapper module / analysis modules Flexible combination of 4 analysis modules at most, fulfilling requirements from multiple laboratories High automation level Automatic sample loading and scanning, automatic weight balanced in centrifuge module without manual operation Intelligent software system Support auto-dilution and auto-retests Monitor real-time instrument status, testing status, reagent reserve and consumables status Application Scenarios Medical Laboratories Indipendent Clinical Laboratory Health Check-up Center Test Menu Technical Specifications Methodology: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Test Items: 118 items. Up to 85 items tested simultaneously Test Speed: Up to 400 T/H Fastest Time for the First Result:12 min Sample Volume: 10 uL~150 uL (1 uL increment) Sample Loading:Sample loading by tracks, sample/return/emergency track Maximum Loading capacity: 190 sample positions Reagent Volume: 10 uL~150 uL (0.1 uL increment) Reagent Tray: 30 reagent positions Cooling Function: internal air circulation cooling with a range of 4~8℃ Cuvettes:Using mainstream circular cuvettes, up to 2000 can be stored in hopper at a time Incubation Temperature: 37±0.2°C Preheating Time:<15 min Magnetic Separator Cleaning: Four-step magnetic separation, four-step cleaning Dimensions: 1100 mm (L) x 930 mm (W) x 1200 mm (H)  
  • Leading Respiratory Trainer Manufacturer
    Leading Respiratory Trainer Manufacturer
    Respiratory Trainer
    The Expiratory Type is an assisted expectoration device specifically developed for patients struggling with phlegm clearance, combining airway vibration and PEP (Positive Expiratory Pressure) therapy. The Inspiratory Type is an inspiratory resistance-type device that can effectively increase lung capacity, exercise respiratory muscles, reduce postoperative complications, and improve respiratory system function.
  • Chemiluminescence Immunoassay Analyzer
    Chemiluminescence Immunoassay Analyzer
    MAGICL 8500 Chemiluminescence Immunoassay Analyzer
    Key Features Intelligent Sample Management Module Compatible with different types of sample tubes Automatic recognition of sample height and tube cap Efficient Track, Emergency in Priority 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority Test Cups and Washing Unit Tilt-pour test cups loading, with a maximum capacity of 2000 Four-step washing for more thorough cleaning Reagent Tray Module 30 reagent positions for simultaneous testing of up to 30 different items RFlD recognition of reagents, dynamic refreshing of reagents status Flexible Expansion Compact footprint Flexible expansion of multiple pre-analytical and clinical chemistry/immunochemistry modules Flexible combination of 4 analytical modules at most Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Techinical Specifications Test Principle: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Throughput: Up to 600 T/H Fastest Time of First Result: 12 min Reaction Cup: Using mainstream circular reaction cup, up to 2000 pieces can be stored at a time Reagent Tray: 30 reagent positions with 2-8 ℃ internal air circulation refrigeration Dimensions: : 1100 mm (L) x 873 mm (W) x 1232 mm (H) Sample Volume: 5 μL~150 μL (1 μL increment) Sample Probe: Probe clog detection, horizontal collision prevention, vertical collision prevention, liquid level detection Reagent Volume: 10 μL~ 150 μL (1 μL increment) Reaction Tray: 183 incubation positions, non-contact vortex mixing Carryover Contamination Rate: < 0.1 PPM Test Cup: Maximum 2000 units  Heating Method: Direct solid heating Magnetic Separation Washing Station: 4-step magnetic separation, 4-step washing  
  • Integrated Immunofluorescence and Hematology Modular System
    Integrated Immunofluorescence and Hematology Modular System
    Metis 6000 Modular System
    Key Features Automatic Automatic & Streamlined workflow to reduce workload Independent emergency track, striving for more treatment time Flexible Flexible expansion enables the combination and collaboration of 1-4 modules Optional choice for SHC 200 system (Centrifuge & Decapper) Compact Metis 6000 takes up only 2.6 m2 for two modules Only increasing 1.0 m2 by upgrading with SHC 200 system (Centrifuge & Decapper) Intelligent Optional SHC 200 pre-analytical module can realize Automatic tube decapping and cap disposal Automatic sample centrifugation Centrifugation time, speed and temperature can be set according to needs Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Technical Specifications MAGICL 6200 Immunochemistry Module Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 400 T/H Fastest Time of First Result: 10 min Reaction Cup: Using mainstream circular reaction cup, up to 2000 pieces can be stored at a time Reagent Tray: 30 reagent positions with 2-8 ℃ internal air circulation refrigeration Dimensions: 1100 mm(L)×930 mm(W)×1200 mm(H) CM-1000 Clinical Chemistry Module Throughput: Constant speed of 1000 T/H; optional ISE module: 400 T/H Simultaneously Detected Items: 61 Cuvettes: 270 quartz glass or plastic cuvettes (optical path: 5 mm)  Reagent Tray: 63 reagent positions for outer tray (20/70 mL) 40 reagent positions for inner tray (20/70 mL)  Dimensions: 1100 mm(L)×930 mm(W)×1200 mm(H)  
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-1000 Clinical Chemistry Analyzer
    Key Features CM-1000 (Standalone Version) Powerfully Compact  Smaller footprint without compromising speed 50 sample positions and support STAT samples Constant throughput: 1000 T/H, optional ISE module with 400 T/H Accurate Sampling System Internally and externally polished sampling probes, high precision Liquid volume tracking and level detection Reagent Module 103 reagent positions, simultaneous testing of up to (61 + 4 ISE) different items  270 quartz glass cuvettes, replaceable individually Advanced Track Unit 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority 8-step Warm Liquid Washing Double-row cleaning design 8-step washing, more thorough cleaning CM-1000 (SH 80 version) Intelligent Sample Processing Unit Constant throughput: 1000 T/H, optional ISE module with 400 T/H 190 sample positions with AI visual recognition for barcode scanning, sample type and tube identification, sample level and serum quality detection Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Reagent Module 103 reagent positions, simultaneous testing of up to (61 + 4 ISE) different items  270 quartz glass cuvettes, replaceable individually Advanced Track Unit 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority 8-step Warm Liquid Washing Double-row cleaning design 8-step washing, more thorough cleaning Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1100 mm (L) * 930 mm (W) * 1200 mm (H) Gross Weight: 400 kg Sample Positions: 190 positions  Reagent Positions: 103 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 40 L purified water per hour Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL  
  • Multiple Channel Portable POCT Analyzer
    Multiple Channel Portable POCT Analyzer
    Getein 1160 Immunofluorescence Quantitative Analyzer
    Key Features Portable Dimensions: 299 mm (L) × 276 mm (W)× 152 mm (H) Weight: 4 kg Instant Results Get results in 3-15 minutes Detection Performance Improved Reduced influence by temperature and improved detection accuracy Reliable Accuracy Good correlation with CLIA methodConvenientEasy to operate, user friendly interfaceAuto Cartridge Collection Automatically receive the used test cards when the test is finishedTechnical Specifications     Application Scenarios ICU Laboratory Emergency Clinic     Test Menu   Technical Specifications Dimensions: 299 mm (W) × 276 mm (D)× 152 mm (H) Weight: 4 kg Printer: Built-in Thermal Printer, support for external printer Display: 10.1'' LCD touch screen  Connectivity: Ethernet port for LIS/HIS COM port for PC ;2 USB ports for software update and file copy Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool  Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese/French Repeatability: CV ≤ 2% within range [100, 15000] mV ; CV ≤ 10% within range [0, 100) mV
  • Leading Whole-body Cryotherapy System Manufacturer
    Leading Whole-body Cryotherapy System Manufacturer
    Whole-body Cryotherapy System
    Product Function Physical Rehabilitation Reduce muscle soreness and accelerate recovery Pain Management Arthritis, Fibromyalgia Syndrome, etc. Mental Health Boost norepinephrine and endorphins, relieve anxiety and depression, and improve sleep quality Beauty and Slimming Promote blood circulation and tighten skin Activate brown fat and boost metabolic rate Immune and Endocrine Regulation Promoting the secretion of testosterone and adrenaline Short-term immune activation (enhanced WBC activity) and long-term stress hormone balance  
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-1600 Clinical Chemistry Analyzer
    Key Features CM-1600 (Standalone Version) Compact and Powerful   Same speed, smaller size with 50 sample positions Single analytical module only occupied 1 m²   Throughput can reach up to 1600 T/H, optional ISE module with 600 T/H Reagent Module 107 reagent positions, simultaneous testing of up to (63 + 3 ISE) different items  277 quartz glass cuvettes, replaceable individually Whole Blood Testing-HbA1c Direct testing supported, no pretreatment needed Fully automated in-machine hemolysis and detection Incubation and optical System Dry heating to maintain the reaction solution in the cuvette at 37.0 ℃  LED light source with a lifespan of 20,000 hours Washing Unit and Sample Probe 8-step cleaning with acid, alkaline, and warm water Equipped with probe clogging detection, horizontal anti-collision, vertical anti-collision Liquid level monitoring, and ultrasonic cleaning function Whole probe stereo cleaning technology with cross contamination rate 0.1 PPM CM-1600(SH 80 version) Advanced Sample Processing Throughput can reach up to 1600 T/H, optional ISE module with 600 T/H 190 sample positions with AI visual recognition for barcode scanning, sample type and tube identification, sample level and serum quality detection Reagent Module 107 reagent positions, simultaneous testing of up to (63 + 3 ISE) different items  277 quartz glass cuvettes, replaceable individually Whole Blood Testing-HbA1c Direct testing supported, no pretreatment needed Fully automated in-machine hemolysis and detection Incubation and optical System Dry heating to maintain the reaction solution in the cuvette at 37.0 ℃  LED light source with a lifespan of 20,000 hours Washing Unit and Sample Probe 8-step cleaning with acid, alkaline, and warm water Equipped with probe clogging detection, horizontal anti-collision, vertical anti-collision Liquid level monitoring, and ultrasonic cleaning function Whole probe stereo cleaning technology with cross contamination rate 0.1 PPM Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Sample Positions: 50 /190 positions Reagent Positions: 107 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Water Consumption: No more than 70 L purified water per hour Minimum Reaction volume: 70 μL Minimum Sampling Volume: 1.0 μL  
  • Integrated Immunofluorescence and Hematology Modular System
    Integrated Immunofluorescence and Hematology Modular System
    Metis 7000 Modular System
    Key Features Automatic Utilizes an automated and streamlined workflow design to significantly reduce manual operational load Independent emergency track, striving for more treatment time Flexible Flexible expansion enables the combination and collaboration of 1-4 modules Optional choice for CS 700 system (Storage, retrieval and disposal) Compact Metis 7000 takes up only 2.5㎡ for two modules (without centrifuge or refrigeration) Only increasing 1.0 ㎡ for adding 1 more analytical module Intelligent Optional CS 700 refrigeration unit can realize: Automated temperature-controlled cold storage for test tubes, quality controls, and calibrators Positioning recognition and automated transfer of sample trays Automatic disposal of expired or waste samples Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu   Techinical Specifications MAGICL 8500 Immunochemistry Module Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 600 T/H Fastest Time of First Result: 12 min Using RFID to dynamically update reagent status Tilt-pour test cup loading, maximum capacity of 2000 units Dimensions: 1100 mm(L)×873 mm(W)×1232 mm(H) CM-1600 Clinical Chemistry Module Throughput: Constant speed of 1600 T/H; optional ISE module: 600 T/H Testing up to 66 items at the same time (ISE included)  Reagent Positions: 107  Sample needle ultrasonic washing Acid solution, alkaline solution, 8-step warm water washing Dimensions: 1100 mm(L)×873 mm(W)×1220 mm(H)  
  • Chemiluminescence Immunoassay Analyzer
    Chemiluminescence Immunoassay Analyzer
    MAGICL 6800 Chemiluminescence Immunoassay Analyzer
    Key Features Support Whole Blood Samples Equipped with HCT module, support W.B. samples, no need for centrifugation Test HCT of W.B. sample and calculate to serum volume, designed for emergency use Complete Automation Automatic sample loading, mixing, decapping and recapping, original tube-based sample in and out operation Add samples with disposable tips to avoid cross-contamination Automatic liquid level detection and pressure recognition to avoid empty aspiration Non-stop Replacement of Consumables Dual consumables trays design, tips and test cups integrated consumables box  Support consumables replacement with no pause, easy for operation High-throughput Sample Management Module 50 sample positions, support continuous sample loading Automatic alarm of empty aspiration and no detection of samples Support STAT mode for emergency Intelligent Reagent Module 24 reagent positions, support on-board loading Silicone stopper puncture technology, prevent reagents from evaporation Automatic recognition of reagents by RFID, eliminate manual RFID scanning Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Techinical Specifications Test Principle: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Throughput: Up to 200 T/H Fastest Time of First Result: 9 min Sample Positions: 50 sample positions Reagent Positions: 24 reagent positions  Sample Type: Whole blood, serum, plasma, urine, fingertip blood Sampling Method: Disposable tips  Test Mode: Batch/Random/STAT  Dimensions: 702 mm (L) * 695 mm (W) * 670 mm (H) Screen: 15.6” LCD full touch screen Data Transmission: LIS/HIS connectivity Sensing Functions: Liquid level detection, bubble detection, probe clogging detection, temperature monitoring, consumables inventory monitoring  
1 2 3 4 5 ... 9

A total of 9 pages

Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Leave A Message

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service