Contact Getein
Search
5 results found for "Clinical Chemistry Instrument"
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-400 Clinical Chemistry Analyzer
    Key Features High-effciency Sample Processing  Constant throughput: 400 T/H, optional ISE module with 400 T/H 90 samples positions, 80 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Bubble detection and probe-clot (clogging) detection Water-quality monitoring module (Optional) and Built-in degassing unit  Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use Intelligent Online Loading System Reagents can be loaded on-board during test Peltier system provides a longer maintenance period to reduce repair probability 8-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1160 mm (L) * 790 mm (W) * 1140 mm (H) Gross Weight: 300 kg Sample Positions: 90 positions  Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 15 L purified water per hour Calibration: multi-point calibration curve with up to 7 points Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL  
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-430 Clinical Chemistry Analyzer
    Key Features Better Cost-effectiveness  One stirrer less — Upgraded mechanics with reduced maintenance High-effciency Sample Processing Constant throughput: 400 T/H, optional ISE module with 400 T/H 90 sample positions, 80 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Bubble detection and probe-clot (clogging) detection Water-quality monitoring module (Optional) and Built-in degassing unit  Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use Intelligent Online Loading System Reagents can be loaded on-board during test Peltier system provides a longer maintenance period to reduce repair probability 8-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1160 mm (L) * 790 mm (W) * 1140 mm (H) Gross Weight: 300 kg Sample Positions: 90 positions  Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 15 L purified water per hour Calibration: multi-point calibration curve with up to 7 points Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL  
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-800 Clinical Chemistry Analyzer
    Key Features High-effciency Sample Processing  Constant throughput: 800 T/H, optional ISE module with 400 T/H 137 samples positions, 114 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ High-efficiency Triple Mix Bars Triple mix bars with two-stage cleaning, avoiding stirring rod contamination Real-time monitoring of stirring speed Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Intelligent Online Loading System Reagents can be loaded on-board during test 9-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Advanced Optical system  Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use (optional) Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1640 mm (L) * 940 mm (W) * 1215 mm (H) Gross Weight: 500 kg Sample Positions: 137 positions  Reagent Positions: 114 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 26 L purified water per hour Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL  
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-1000 Clinical Chemistry Analyzer
    Key Features CM-1000 (Standalone Version)- Powerfully Compact  Smaller footprint without compromising speed 50 sample positions and support STAT samples Constant throughput: 1000 T/H, optional ISE module with 400 T/H Accurate Sampling System Internally and externally polished sampling probes, high precision Liquid volume tracking and level detection Reagent Module 103 reagent positions, simultaneous testing of up to (61 + 4 ISE) different items  270 quartz glass cuvettes, replaceable individually Advanced Track Unit 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority 8-step Warm Liquid Washing Double-row cleaning design 8-step washing, more thorough cleaning CM-1000 (SH 80 version)-Intelligent Sample Processing Unit Constant throughput: 1000 T/H, optional ISE module with 400 T/H 190 sample positions with AI visual recognition for barcode scanning, sample type and tube identification, sample level and serum quality detection Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Reagent Module 103 reagent positions, simultaneous testing of up to (61 + 4 ISE) different items  270 quartz glass cuvettes, replaceable individually Advanced Track Unit 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority 8-step Warm Liquid Washing Double-row cleaning design 8-step washing, more thorough cleaning Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1100 mm (L) * 930 mm (W) * 1200 mm (H) Gross Weight: 400 kg Sample Positions: 190 positions  Reagent Positions: 103 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 40 L purified water per hour Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL  
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-1600 Clinical Chemistry Analyzer
    Key Features CM-1600 (Standalone Version) -Compact and Powerful   Same speed, smaller size with 50 sample positions Single analytical module only occupied 1 m²   Throughput can reach up to 1600 T/H, optional ISE module with 600 T/H Reagent Module 107 reagent positions, simultaneous testing of up to (63 + 3 ISE) different items  277 quartz glass cuvettes, replaceable individually Whole Blood Testing-HbA1c Direct testing supported, no pretreatment needed Fully automated in-machine hemolysis and detection Incubation and optical System Dry heating to maintain the reaction solution in the cuvette at 37.0 ℃  LED light source with a lifespan of 20,000 hours Washing Unit and Sample Probe 8-step cleaning with acid, alkaline, and warm water Equipped with probe clogging detection, horizontal anti-collision, vertical anti-collision Liquid level monitoring, and ultrasonic cleaning function Whole probe stereo cleaning technology with cross contamination rate 0.1 PPM CM-1600(SH 80 version) -Advanced Sample Processing Throughput can reach up to 1600 T/H, optional ISE module with 600 T/H 190 sample positions with AI visual recognition for barcode scanning, sample type and tube identification, sample level and serum quality detection Reagent Module 107 reagent positions, simultaneous testing of up to (63 + 3 ISE) different items  277 quartz glass cuvettes, replaceable individually Whole Blood Testing-HbA1c Direct testing supported, no pretreatment needed Fully automated in-machine hemolysis and detection Incubation and optical System Dry heating to maintain the reaction solution in the cuvette at 37.0 ℃  LED light source with a lifespan of 20,000 hours Washing Unit and Sample Probe 8-step cleaning with acid, alkaline, and warm water Equipped with probe clogging detection, horizontal anti-collision, vertical anti-collision Liquid level monitoring, and ultrasonic cleaning function Whole probe stereo cleaning technology with cross contamination rate 0.1 PPM Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Sample Positions: 50 /190 positions Reagent Positions: 107 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Water Consumption: No more than 70 L purified water per hour Minimum Reaction volume: 70 μL Minimum Sampling Volume: 1.0 μL  

A total of 1 pages

Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Leave A Message

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service