Contact Getein
Search
187 results found for "Analyzer"
  • 3-part Veterinary Automatic Hematology Analyzer
    3-part Veterinary Automatic Hematology Analyzer
    BHA-3000 Vet Automatic Hematology Analyzer
    Key Features Fast Test Utilizing double-channel test mode No Residue No residue of hematology diluent or lysing reagent;Cost effective Easy and Convenient Operation Large LCD touch screen High-definition color monitor, no need of external computer Built-in printer to fast print test results Supports Wi-Fi data transmission for printing A4 reports on Ani-Q Optimized Liquid System Very low failure rate & excellent maintainability Intelligent Floating Threshold Making the classification more accurate Techinical Specifications 19 Reportable Parameters: WBC, NEU#, MXD#, LYM#, NEU%, MXD%, LYM%, RBC, HGB, MCV, RDW-CV, MCHC, MCH, RDW-SD, HCT, PLT, MPV, PDW, PCT Principles: Classic Electrical Impedance Method, Mature Photoelectric Colorimetry Sample Mode: Whole Blood Sample Volume: Venous blood: 10 μL QC Methods: L-J QC, X-B QC Data Storage: 10000 Screen Type: 10.4 inch Resistive Screen Power Supply: 100-240 V~ 50/60 Hz Weight: 16 kg Dimension: 328 mm x 425 mm x 446 mm (L x W x H) Operating Conditions: 18~30℃, ≤80% Relative Humidity, 75 kPa~106 kPa  
  • Chemiluminescence Immunoassay Analyzer
    Chemiluminescence Immunoassay Analyzer
    MAGICL 8500 Chemiluminescence Immunoassay Analyzer
    Key Features Intelligent Sample Management Module Compatible with different types of sample tubes Automatic recognition of sample height and tube cap Efficient Track, Emergency in Priority 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority Test Cups and Washing Unit Tilt-pour test cups loading, with a maximum capacity of 2000 Four-step washing for more thorough cleaning Reagent Tray Module 30 reagent positions for simultaneous testing of up to 30 different items RFlD recognition of reagents, dynamic refreshing of reagents status Flexible Expansion Compact footprint Flexible expansion of multiple pre-analytical and clinical chemistry/immunochemistry modules Flexible combination of 4 analytical modules at most Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Techinical Specifications Test Principle: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Throughput: Up to 600 T/H Fastest Time of First Result: 12 min Reaction Cup: Using mainstream circular reaction cup, up to 2000 pieces can be stored at a time Reagent Tray: 30 reagent positions with 2-8 ℃ internal air circulation refrigeration Dimensions: : 1100 mm (L) x 873 mm (W) x 1232 mm (H) Sample Volume: 5 μL~150 μL (1 μL increment) Sample Probe: Probe clog detection, horizontal collision prevention, vertical collision prevention, liquid level detection Reagent Volume: 10 μL~ 150 μL (1 μL increment) Reaction Tray: 183 incubation positions, non-contact vortex mixing Carryover Contamination Rate: < 0.1 PPM Test Cup: Maximum 2000 units  Heating Method: Direct solid heating Magnetic Separation Washing Station: 4-step magnetic separation, 4-step washing  
  • Immunofluorescence Quantitative Analyzer
    Immunofluorescence Quantitative Analyzer
    Getein 1600 Immunofluorescence Quantitative Analyzer
    Key Features Instant Results Get results in 3-15 minutes Most Advanced  The Getein1600 Fully Automated Fluorescence Immunoassay Analyzer is a pioneering product in the international POCT (Point-of-Care Testing) field, representing a breakthrough in high-end automated technology for domestic POCT products. More Convenient Fully automated, it can complete the entire process of quality control, sample aspiration, dilution, mixing, measurement, calculation, and report printing. It supports automatic program upgrades and integration with LIS and HIS systems. More Functional Features random sample insertion, allowing for immediate testing of emergency samples at any time. More Efficient Requires only a minimum of 10 µL sample volume for detection and supports testing of whole blood, serum, plasma, and urine samples. More Aesthetic Equipped with an Android operating system and a 10.4-inch LCD touchscreen display, it offers easy operation, a modular structure, and software for convenient upgrades and maintenance. High Throughput Capable of simultaneously testing three different parameters from the same sample, it can process up to 48 samples at once, with a throughput of up to 150 samples per hour. The average detection time is less than 30 seconds per sample. Application Scenarios ICU Laboratory Emergency Clinic     Test Menu Technical Specifications Dimensions: 639mm(W)×562mm(D)×728mm(H) Weight: 45 kg Sample Positions: 48 Reagent Positions: 4*24/48 Printer: Built-in Thermal Printer, support for external printer Display: 10.1'' LCD touch screen  Connectivity: Ethernet port for LIS/HIS COM port for PC Calibration: RFID Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese Cases Storage: Over 500,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV  
  • MAGICL hs-cTnI (CLIA) Test Kit
    MAGICL hs-cTnI (CLIA) Test Kit
    MAGICL hs-cTnI (CLIA)
    MAGICL hs-cTnl (CLlA) is intended for the in vitro quantitative determination of high-sensitivity cardiac troponin l (hs-cTnl) in human serum, plasma and whole blood samples.
  • 5-part Veterinary Automatic Hematology Analyzer
    5-part Veterinary Automatic Hematology Analyzer
    BHA-5000 Vet Automatic Hematology Analyzer
    Key Features Principles Laser scatter in flow cytometry Classic electrical impedance method Mature photoelectric colorimetry Fast Test Use double-channel test mode with 60 T/H More Accurate Test Use optical method to detect Basophil Curve fitting, floating threshold technology lntelligent scatter classification technology The smallest gem hole in the industry with high sensitivity Digital filtering, coincidence correction in blood cell counting Optical Method for BASO: Avoid errors caused by the partial Technical Specifications 23 Reportable Parameters:RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, WBC, NEU (#), LYM (#), MON (#), EOS (#), BAS (#), NEU (%), LYM (%), MON (%), EOS (%), BAS (%), PLT, MPV, PDW, PCT Analysis Speed: 60 T/H Screen Size: 10.1-inch touch screen Whole Blood Sample Volume: 30 μL Supported Languages: Chinese, English, Russian, Spanish Printer: Built-in thermal printer, supports WiFi data transmission   Supported Species: Cat, dog, and one user-defined animal species Detection Principles: Laser flow cytometry, photoelectric colorimetry 50 μm Gem Aperture: Ensures precise Red Blood Cell (RBC) detection  
  • Fully Automated Immunofluorescence Quantitative Analyzer
    Fully Automated Immunofluorescence Quantitative Analyzer
    Getein 1200 Immunofluorescence Quantitative Analyzer
    Key Features Instant Results Get results in 3-15 minutes High Throughput Capable of processing multiple samples simultaneously, ensuring fast turnaround times Accuracy and Precision Utilizes advanced immunofluorescence technology to deliver highly accurate and reproducible results User-Friendly Interface  Equipped with a touch-screen interface for easy operation and minimal training requirements Versatile Applications Suitable for a wide range of tests, including cardiac markers, inflammation markers, fertility tests, and more Compact Design Space-saving design that fits well in various laboratory settings without compromising performance Application Scenarios ICU Laboratory Emergency Clinic     Test Menu Technical Specifications Dimensions: 675 mm(W)×570 mm(D)×574 mm(H) Weight: 43 kg Sample Positions: 50 Reagent Positions: 4*24/48 Printer: Built-in Thermal Printer, support for external printer Display: 12.1'' LCD touch screen  Connectivity: Bidirectional LiS/HS connectivity Calibration: RFID Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese Cases Storage: Over 100,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
  • MAGICL hs-cTnT (CLIA) Test Kit
    MAGICL hs-cTnT (CLIA) Test Kit
    MAGICL hs-cTnT (CLIA)
    MAGICL hs-cTnT (CLlA) is intended for the in vitro quantitative determination of highly-sensitive cardiac troponin T (hs-cTnT) in human serum, plasma or whole blood.
  • Hand-held chemistry and immunofluorescence analyzer
    Hand-held chemistry and immunofluorescence analyzer
    Getein 208 Immunofluorescence Quantitative Analyzer
    Benefits where you need Instant Results Get results in 3-15 minutes Detection Performance Improved Reduced influence by temperature and improved detection accuracy Dry clinical chemistry and immunofluorescence Supporting multiple test items Combo test, highly efficient Reliable Accuracy Good correlation with CLIA method 32℃ constant test environment Convenient Easy to operate, user friendly interface Benefits where you need ICU Laboratory Emergency Clinic     Test Menu   Technical Specifications Dimensions: 160 mm × 80 mm × 24 mm (D×W×H)  Weight: 256 g Printer: Support for external Bluetooth thermal printer  Connectivity: USB/Bluetooth/WIFI Calibration: SD Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool  Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Chinese Cases Storage: Over 10,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
1 ... 3 4 5 6 7 ... 24

A total of 24 pages

Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Leave A Message

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service