Key Features High-Efficiency Autoloader Continuous rack loading, no need to pause testing More efficient workflow High-Efficiency Sample Processing Optional ISE module: 600 T/H 93 cuvettes: quartz glass or plastic Whole Blood Testing-HbA1c Direct testing with whole blood samples; automatic on-board hemolysis and analysis No manual pre-treatment required, ensuring higher accuracy Simplified operation and improved testing efficiency IFCC and NGSP standardization Air Bath Heating System Constant-temperature air bath with rapid heating reduces instrument warm-up time and requires no maintenance The temperature control system utilizes dry heating to maintain the reaction solution in the cuvette at 37 ℃ Compact and Connectable Integrated with the MAGICL 6100 to form the Metis 600, the smallest clinical chemistry and immunochemistry modular system on the market—maximizing space savings while also shortening turnaround time 6-Step Warm Liquid Washing Cross-contamination rate < 0.1PPM Water consumption: 15 L/H and 2-step washing solution + 4-step purified water washing Intelligent 3D full-needle washing technology and ultrasonic cleaning system Automatic wash solution dilution Accurate Sampling System Minimum reaction volume: 100 μL Highly-precise injector, internally and externally polished sampling probes, liquid level detection and bubble detection Advanced Optical System LED light source with high stability, long lifespan optical system with diffraction grating and 16 wavelengths Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 960 mm (L) × 770 mm (W) × 655 mm (H) Sample Positions: 60 positions Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes Water Consumption: No more than 15 L purified water per hour Minimum Reaction Volume: 100 μL
Key Features High-Efficiency Autoloader Continuous rack loading, no need to pause testing More efficient workflow High-Efficiency Sample Processing Optional ISE module: 600 T/H 93 cuvettes: quartz glass or plastic Whole Blood Testing-HbA1c Direct testing with whole blood samples; automatic on-board hemolysis and analysis No manual pre-treatment required, ensuring higher accuracy Simplified operation and improved testing efficiency IFCC and NGSP standardization Air Bath Heating System Constant-temperature air bath with rapid heating reduces instrument warm-up time and requires no maintenance The temperature control system utilizes dry heating to maintain the reaction solution in the cuvette at 37 ℃ Compact and Connectable Integrated with the MAGICL 6100 to form the Metis 600, the smallest clinical chemistry and immunochemistry modular system on the market—maximizing space savings while also shortening turnaround time 6-Step Warm Liquid Washing Cross-contamination rate < 0.1PPM Water consumption: 15 L/H and 2-step washing solution + 4-step purified water washing Intelligent 3D full-needle washing technology and ultrasonic cleaning system Automatic wash solution dilution Accurate Sampling System Minimum reaction volume: 100 μL Highly-precise injector, internally and externally polished sampling probes, liquid level detection and bubble detection Advanced Optical System LED light source with high stability, long lifespan optical system with diffraction grating and 16 wavelengths Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 960 mm (L) × 770 mm (W) × 655 mm (H) Sample Positions: 60 positions Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes Water Consumption: No more than 15 L purified water per hour Minimum Reaction Volume: 100 μL