Key Features Compact and Powerful Same speed, smaller size Single analytical module only occupied 1 m² Throughput can reach up to 1600 T/H Reagent Module 107 reagent positions, simultaneous testing of up to (63 + 3ISE) different items 277 quartz glass cuvettes, replaceable individually Whole Blood Testing-HbA1c Direct testing supported, no pretreatment needed Fully automated in-machine hemolysis and detection Incubation and Detection System Dry heating to maintain the reaction solution in the cuvette at 37.0 ℃ LED light source with a lifespan of 20,000 hours Washing Unit and Sample Probe 8-step cleaning with acid, alkaline, and warm water Equipped with probe clogging detection, horizontal anti-collision, vertical anti-collision liquid level monitoring, and ultrasonic cleaning function Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Sample Positions: 50 /190 positions Reagent Positions: 107 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Water Consumption: No more than 70 L purified water per hour Minimum Reaction volume: 70 μL Minimum Sampling Volume: 1.0 μL
Key Features Compact and Powerful Same speed, smaller size Single analytical module only occupied 1 m² Throughput can reach up to 1600 T/H Reagent Module 107 reagent positions, simultaneous testing of up to (63 + 3ISE) different items 277 quartz glass cuvettes, replaceable individually Whole Blood Testing-HbA1c Direct testing supported, no pretreatment needed Fully automated in-machine hemolysis and detection Incubation and Detection System Dry heating to maintain the reaction solution in the cuvette at 37.0 ℃ LED light source with a lifespan of 20,000 hours Washing Unit and Sample Probe 8-step cleaning with acid, alkaline, and warm water Equipped with probe clogging detection, horizontal anti-collision, vertical anti-collision liquid level monitoring, and ultrasonic cleaning function Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Sample Positions: 50 /190 positions Reagent Positions: 107 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Water Consumption: No more than 70 L purified water per hour Minimum Reaction volume: 70 μL Minimum Sampling Volume: 1.0 μL