Key Features Sample In — Result Out Fully automated nucleic acid extraction → PCR amplification → detection → analysis Fully Enclosed Kit Paired with exclusive patent⸺fully enclosed microfluidic reagent chip, avoids operational and instrumental contamination Multiple Tests Detection Multiple tests at once, maximizing workflow and save time Easy Operation Require minimal training and hands-on time Quick Test Fastest turnaround time of 35 min from sample to result Application Scenarios Vet Clinics Animal Farm Large Pet Hospital Test Menu Techinical Specifications Principle: Real-time Quantitative PCR Weight: 9.5 kg Module Number: 2 Detection Channels: 4 Sample Repeatability: CV≤3% Thermal Cycling Tech: Peltier Light Source: LED Sample Linearity: ≥0.98 Reagent Parameter Import: QR Code Scan Recognition Temperature Uniformity: ±1℃ Sample Volume: 60 μL EDTA Whole Blood (Other types ref. manual) Dimensions: 419(L) x 310(W) x 233(H) mm Power Parameters: AC 220V±22V, 50Hz±1Hz Display: 10.1-inch Touch Screen Supported Languages: Chinese, English, Spanish Ramp Rate: Max Heating ≥8℃/s, Max Cooling ≥7℃/s
Key Features Simplified Diagnostic Process One-button switch design Real-time status monitoring Full-process automated testing Whole Blood Testing — One-Tube Solution Whole blood testing in one tube, no centrifugation required One-time sampling, entry, and loading shortens sample turnaround time Pre-loaded tray for 200 samples, freeing operators' hands Efficient Dual-track Design Inner track for sample testing, providing sample tube caching function Outer track for sample tube rack rapid allocating Capillary Blood Testing Batch processing of capillary blood samples, addressing challenges in blood collection for difficult-to-draw patients Comprehensive test menu, covering women's and pediatric health with ease Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu
Key Features High-effciency Sample Processing Constant throughput: 800 T/H, optional ISE module with 400 T/H 137 samples positions, 114 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ High-efficiency Triple Mix Bars Triple mix bars with two-stage cleaning, avoiding stirring rod contamination Real-time monitoring of stirring speed Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Intelligent Online Loading System Reagents can be loaded on-board during test 9-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use (optional) Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1640 mm (L) * 940 mm (W) * 1215 mm (H) Gross Weight: 500 kg Sample Positions: 137 positions Reagent Positions: 114 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes Water Consumption: No more than 26 L purified water per hour Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL
Key Features Highly Efficient & Accurate Advanced fluorescence immunoassay Multiple quality control Convenient Operation RFID card calibration Continuous test for 3 hours with lithium battery Real-time and Rapid Test 3-15 min/test 5 sec/test for multiple tests User-friendly Interface Android system 7-inch touch screen Application Scenarios ICU Laboratory Emergency Clinic Test Menu Technical Specifications Methodology: Fluorescence Immunochromatography Channels: Single channel Sample Types: Serum, plasma, whole blood, urine, feces, fingertip blood, nasal swab, saliva Detection Time: 3-15 minutes Printer: Built-in thermal printer, paper size 5735 mm Display: 7.0-inch LCD color capacitive touchscreen, resolution 1024600, supports touch and handwriting operations Dimensions: 261 mm (L) × 241 mm (W) × 115 mm (H) Net Weight: Main unit 2000g, power adapter 430g, lithium battery pack (optional) 300g Operating System: Android system Data Storage: Stores 10,000 results (reagent storage capacity of 100,000, but excessive storagemay cause the Android system to crash; timely data cleanup is recommended) Communication Input: One SD card (old) slot, two USB ports Communication Output: One RS232 serial port, one Ethernet port Languages: English, Chinese, Spanish, Portuguese Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
Key Features Fast And accurate tests with small footprint High throughput at 400 T/H can satisfy needs from different hospitals and laboratories Compact footprint, maximizing space utilization efficiency Flexible expansion for modular system Support expansion of centrifuge and decapper module / analysis modules Flexible combination of 4 analysis modules at most, fulfilling requirements from multiple laboratories High automation level Automatic sample loading and scanning, automatic weight balanced in centrifuge module without manual operation Intelligent software system Support auto-dilution and auto-retests Monitor real-time instrument status, testing status, reagent reserve and consumables status Application Scenarios Medical Laboratories Independent Clinical Laboratory Health Check-up Center Test Menu Technical Specifications Methodology: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Test Items: 118 items. Up to 85 items tested simultaneously Test Speed: Up to 400 T/H Fastest Time for the First Result:12 min Sample Volume: 10 uL~150 uL (1 uL increment) Sample Loading:Sample loading by tracks, sample/return/emergency track Maximum Loading capacity: 190 sample positions Reagent Volume: 10 uL~150 uL (0.1 uL increment) Reagent Tray: 30 reagent positions Cooling Function: internal air circulation cooling with a range of 4~8℃ Cuvettes:Using mainstream circular cuvettes, up to 2000 can be stored in hopper at a time Incubation Temperature: 37±0.2°C Preheating Time:<15 min Magnetic Separator Cleaning: Four-step magnetic separation, four-step cleaning Dimensions: 1100 mm (L) x 930 mm (W) x 1200 mm (H)
Key Features Reliable & Accurate Provide high-quality testing Advanced immunofluorescence quantitative technology Instant Testing Get results in 3-15 min One sample can be tested in 5 sec at the fastest with multiple test items Smooth Operation Automatic reading of test items Real-time auto-printing and uploading Large display, Android system, user-friendly interface Multi-scene Application Small in size, lithium-ion battery (optional) Apply to multiple scenarios Support WIFI, convenient data transmission, free of network cables Application Scenarios Vet Clinics Animal Farm Large Pet Hospital Test Menu Technical Specifications Test Principle: Immunofluorescence Sample Type: Serum, Plasma, Whole Blood, Stool, Eye Secretion, Nose Secretion, Saliva Sample Volume: 10-100 μL Dimensions: 261 mm (W) x 241 mm (D) x 115 mm (H) Weight: 2 kg Printer: Built-in thermal printer Display: 7.0-inch LCD color capacitive display, support touch and handwriting operation Language: English/Chinese
Key Features Intelligent Sample Management Module Compatible with different types of sample tubes Automatic recognition of sample height and tube cap Efficient Track, Emergency in Priority 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority Test Cups and Washing Unit Tilt-pour test cups loading, with a maximum capacity of 2000 Four-step washing for more thorough cleaning Reagent Tray Module 30 reagent positions for simultaneous testing of up to 30 different items RFlD recognition of reagents, dynamic refreshing of reagents status Flexible Expansion Compact footprint Flexible expansion of multiple pre-analytical and clinical chemistry/immunochemistry modules Flexible combination of 4 analytical modules at most Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Techinical Specifications Test Principle: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Throughput: Up to 600 T/H Fastest Time of First Result: 12 min Reaction Cup: Using mainstream circular reaction cup, up to 2000 pieces can be stored at a time Reagent Tray: 30 reagent positions with 2-8 ℃ internal air circulation refrigeration Dimensions: : 1100 mm (L) x 873 mm (W) x 1232 mm (H) Sample Volume: 5 μL~150 μL (1 μL increment) Sample Probe: Probe clog detection, horizontal collision prevention, vertical collision prevention, liquid level detection Reagent Volume: 10 μL~ 150 μL (1 μL increment) Reaction Tray: 183 incubation positions, non-contact vortex mixing Carryover Contamination Rate: < 0.1 PPM Test Cup: Maximum 2000 units Heating Method: Direct solid heating Magnetic Separation Washing Station: 4-step magnetic separation, 4-step washing
Key Features Automatic Automatic & Streamlined workflow to reduce workload Independent emergency track, striving for more treatment time Flexible Flexible expansion enables the combination and collaboration of 1-4 modules Optional choice for SHC 200 system (Centrifuge & Decapper) Compact Metis 6000 takes up only 2.6 m2 for two modules Only increasing 1.0 m2 by upgrading with SHC 200 system (Centrifuge & Decapper) Intelligent Optional SHC 200 pre-analytical module can realize Automatic tube decapping and cap disposal Automatic sample centrifugation Centrifugation time, speed and temperature can be set according to needs Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Technical Specifications CA 5700 Coagulation Module Methodology: Clot, chromogenic and immunoturbidimetric principles Throughput: 400 T/H Reagent Positions: 40 tilted reagent positions (refrigerated), 5 tilted dilution positions (room temperature) Dimensions: 1670 mm (L) x 922 mm (W) x 1310 mm (H) MAGICL 6200 Immunochemistry Module Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 400 T/H Fastest Time of First Result: 12 min Reaction Cup: Using mainstream circular reaction cup, up to 2000 pieces can be stored at a time Reagent Tray: 30 reagent positions with 2-8 ℃ internal air circulation refrigeration Dimensions: 1100 mm (L) x 930 mm (W) x 1200 mm (H) CM-1000 Clinical Chemistry Module Throughput: Constant speed of 1000 T/H; optional ISE module: 400 T/H Simultaneously Detected Items: 61 Cuvettes: 270 quartz glass or plastic cuvettes (optical path: 5 mm) Reagent Tray: 63 reagent positions for outer tray (20/70 mL) 40 reagent positions for inner tray (20/70 mL) Dimensions: 1100 mm (L) x 930 mm (W) x 1200 mm (H)