  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-430 Clinical Chemistry Analyzer
    Key Features Better Cost-effectiveness  One stirrer less — Upgraded mechanics with reduced maintenance High-effciency Sample Processing Constant throughput: 400 T/H, optional ISE module with 400 T/H 90 sample positions, 80 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Bubble detection and probe-clot (clogging) detection Water-quality monitoring module (Optional) and Built-in degassing unit  Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use Intelligent Online Loading System Reagents can be loaded on-board during test Peltier system provides a longer maintenance period to reduce repair probability 8-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1160 mm (L) * 790 mm (W) * 1140 mm (H) Gross Weight: 300 kg Sample Positions: 90 positions  Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 15 L purified water per hour Calibration: multi-point calibration curve with up to 7 points Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL  
  • Compact POC PCR Analyzer
    Compact POC PCR Analyzer
    GN 7120 Akso PCR System
    Key Features Sample In - Result Out Compact design &All-in-One system Fully automated nucleic acid extraction→PCR amplification→detection→analysis Quick Test Fastest turnaround time of 35 min from sample to result High Throughput Dual-module design, 12 test channels Multiple items could be detected simultaneously Room Temperature Transportation & Storage Advanced technology, freeze-dried reagent Convenient and cost- effective transportation Applicable Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Real-time PCR Time for the Result: 35 min Channels: 12 Module Number: 2 Sample Type: Nasopharyngeal swab, conjunctiva swab, anal swab, feces, whole blood, serum, oral and nasal secretion, genital tract swab, urinary tract swab, lesion exudate, cervical swab, sputum Thermal Cycling Technology: Peltier Dimensions: 424mm(L)*420 mm(W)*234 mm(H) Weight: 13 kg  
  • Chemiluminescence Immunoassay Analyzer
    Chemiluminescence Immunoassay Analyzer
    MAGICL 6000i Chemiluminescence Immunoassay Analyzer
    Key Features Compact Design Bench top design Relatively lighter weight: 80 kg High Efficiency Throughput: up to 200 T/HFastest time for the first result: 10 min Dual-Tray Consumable Design 2 independent consumable trays, support replacement without pause 140 reaction cups per tray Smooth Reagent Management 24 reagent positions, support online loading PE film puncture technology, preventing reagents from evaporationEquipped with RFID, automatic identification of reagent information Application Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 200 T/H Fastest Time for the First Result: 10 min Reagent Positions: 24 Sample Positions: 50 Sample Type: Serum, plasma, urine, fingertip blood Application Scenarios: Laboratory, Clinics, Emergency, ICU, Wards Sampling Method: Steel needle STAT: Support STAT mode Sensing Functions: Liquid level detection, residual monitoring of reagent and sample, anti-collision Reaction Cups: 2 individuals consumble trays with 140 reaction cups each Reaction Temperature: 37℃±0.5℃ Magnetic Seperation & Washing: 3-step magnetic separation and 3-step washing Dimensions: 685 mm(L)*690 mm(W)*660 mm(H) Weight: 80 kg
  • Integrated Immunofluorescence and Hematology Modular System
    Integrated Immunofluorescence and Hematology Modular System
    Metis 600 Modular System
    Key Features Maximizing the potential of the laboratory Metis 600 modular system provides suitable solutions for immunofluorescence and hematology testing in low volume laboratories Standardization Improve laboratory efficiency through the highest level of automation Reliability Maximize reliable results with industry-leading instrument accuracy and service Rapid Accelerate turnaround time for high-volume sample testing and achieve new levels of rapid service Capacity The combination of Immunofluorescence and Hematology methodologies allows for a more comprehensive test items to be offered Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Technical Specifications BHA-5100 Automatic Hematology Analyzer Dimensions: 705 mm (L) x 670 mm (W) x 570 mm (H) Weight: 21 kg Methodology: Flow cytometry, impedance method, colorimetry Throughput: 60 T/H Test Items: 25 reportable parameters Quality Control Method: L-J quality control, X-B quality control Storage Capacity: > 100, 000 patient data Gem Hole: 50 μm Sample Volume: 15 μL Reagents: 1 diluent and 2 lysers Getein 1200 Immunofluorescence Quantitative Analyzer Dimensions: 570 mm (L) x 675 mm (W) x 574 mm (H) Weight: 43 kg   Methodology: Quantitative immunofluorescence Sample Positions: 50, continuous sample loading Reagent Positions: 4 x 24/48 Throughput: 100 T/H Test Items: 59 items in 13 fields Storage Capacity: 100, 000 test results Dry System: ADP aspiration, no liquid path Automation: Automatic sample loading, mixing and decapping  
  • Integrated Immunofluorescence and Hematology Modular System
    Integrated Immunofluorescence and Hematology Modular System
    Metis 800 Modular System
    Key Features Simplified Diagnostic Process One-button switch design  Real-time status monitoring  Full-process automated testing Whole Blood Testing — One-Tube Solution Whole blood testing in one tube, no centrifugation required One-time sampling, entry, and loading shortens sample turnaround time Pre-loaded tray for 200 samples, freeing operators' hands Efficient Dual-track Design Inner track for sample testing, providing sample tube caching function Outer track for sample tube rack rapid allocating   Capillary Blood Testing Batch processing of capillary blood samples, addressing challenges in blood collection for difficult-to-draw patients Comprehensive test menu, covering women's and pediatric health with ease Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Techinical Specifications BHA-5100 Automatic Hematology Analyzer Dimensions: 705 mm (L) x 670 mm (W) x 570 mm (H) Weight: 21 kg Methodology: Flow cytometry, impedance method, colorimetry Throughput: 60 T/H Test Items: 25 reportable parameters Quality Control Method: L-J quality control, X-B quality control Storage Capacity: > 100, 000 patient data Gem Hole: 50 μm Sample Volume: 15 μL Reagents: 1 diluent and 2 lysers Getein 1200 Immunofluorescence Quantitative Analyzer Dimensions: 570 mm (L) x 675 mm (W) x 574 mm (H) Weight: 43 kg   Methodology: Quantitative immunofluorescence Sample Positions: 50, continuous sample loading Reagent Positions: 4 x 24/48 Throughput: 100 T/H Test Items: 59 items in 13 fields Storage Capacity: 100, 000 test results Dry System: ADP aspiration, no liquid path Automation: Automatic sample loading, mixing and decapping      
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-800 Clinical Chemistry Analyzer
    Key Features High-effciency Sample Processing  Constant throughput: 800 T/H, optional ISE module with 400 T/H 137 samples positions, 114 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ High-efficiency Triple Mix Bars Triple mix bars with two-stage cleaning, avoiding stirring rod contamination Real-time monitoring of stirring speed Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Intelligent Online Loading System Reagents can be loaded on-board during test 9-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Advanced Optical system  Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use (optional) Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1640 mm (L) * 940 mm (W) * 1215 mm (H) Gross Weight: 500 kg Sample Positions: 137 positions  Reagent Positions: 114 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 26 L purified water per hour Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL  
  • Chemiluminescence Immunoassay Analyzer
    Chemiluminescence Immunoassay Analyzer
    MAGICL 6200 Chemiluminescence Immunoassay Analyzer
    Key Features Fast And accurate tests with small footprint High throughput at 400 T/H can satisfy needs from different hospitals and laboratories Compact footprint, maximizing space utilization efficiency Flexible expansion for modular system Support expansion of centrifuge and decapper module / analysis modules Flexible combination of 4 analysis modules at most, fulfilling requirements from multiple laboratories High automation level Automatic sample loading and scanning, automatic weight balanced in centrifuge module without manual operation Intelligent software system Support auto-dilution and auto-retests Monitor real-time instrument status, testing status, reagent reserve and consumables status Application Scenarios Medical Laboratories Indipendent Clinical Laboratory Health Check-up Center Test Menu Technical Specifications Methodology: Acridinium ester direct chemiluminescence Analysis Methods: Sandwich method, competition method Test Items: 118 items. Up to 85 items tested simultaneously Test Speed: Up to 400 T/H Fastest Time for the First Result:12 min Sample Volume: 10 uL~150 uL (1 uL increment) Sample Loading:Sample loading by tracks, sample/return/emergency track Maximum Loading capacity: 190 sample positions Reagent Volume: 10 uL~150 uL (0.1 uL increment) Reagent Tray: 30 reagent positions Cooling Function: internal air circulation cooling with a range of 4~8℃ Cuvettes:Using mainstream circular cuvettes, up to 2000 can be stored in hopper at a time Incubation Temperature: 37±0.2°C Preheating Time:<15 min Magnetic Separator Cleaning: Four-step magnetic separation, four-step cleaning Dimensions: 1100 mm (L) x 930 mm (W) x 1200 mm (H)  