Key Features Portable Dimensions: 299 mm (W) × 276 mm (D)× 152 mm (H) Weight: 4 kg Instant Results Get results in 3-15 minutes Detection Performance Improved Reduced influence by temperature and improved detection accuracy Reliable Accuracy Good correlation with CLIA methodConvenientEasy to operate, user friendly interfaceAuto Cartridge Collection Automatically receive the used test cards when the test is finishedTechnical Specifications Application Scenarios ICU Laboratory Emergency Clinic Test Menu Technical Specifications Dimensions: 299 mm (W) × 276 mm (D)× 152 mm (H) Weight: 4 kg Printer: Built-in Thermal Printer, support for external printer Display: 10.1'' LCD touch screen Connectivity: Ethernet port for LIS/HIS COM port for PC ;2 USB ports for software update and file copy Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese/French Repeatability: CV ≤ 2% within range [100, 15000] mV ; CV ≤ 10% within range [0, 100) mV
Key Features High-effciency Sample Processing Constant throughput: 400 T/H, optional ISE module with 400 T/H 90 samples positions, 80 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Bubble detection and probe-clot (clogging) detection Water-quality monitoring module (Optional) and Built-in degassing unit Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use Intelligent Online Loading System Reagents can be loaded on-board during test Peltier system provides a longer maintenance period to reduce repair probability 8-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1160 mm (L) * 790 mm (W) * 1140 mm (H) Gross Weight: 300 kg Sample Positions: 90 positions Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes Water Consumption: No more than 15 L purified water per hour Calibration: multi-point calibration curve with up to 7 points Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL
Key Features Reliable and accurate results Advanced immunofluorescence quantitative technology Provide high-quality testing multi-scene application Small in size, lithium-ion battery (optional) Support WIFi, convenient data transmission, free of network cables Apply to multiple scenarios instant testing Get results in 3-10 min One sample can be tested in 5 sec at the fastest with multiple test items Smooth Operation Large display, android system, user-friendly interface Real-time auto-printing and uploading Application Scenarios Vet Clinics Animal Farm Large Pet Hospital Technical Specifications Test Principle: Immunofluorescence Sample Type: Serum, Plasma, Whole Blood, Stool, Eye Secretion, Nose Secretion Reaction Time: 3-10 min Sample Volume: 10-15 μL Dimensions: 261 mm (W) x 241 mm (D) x 115 mm (H) Weight: 2 kg Printer: Internal Printer Storage Capacity: 10,000 data Language: English/Chinese
Key Features Better Cost-effectiveness One stirrer less — Upgraded mechanics with reduced maintenance High-effciency Sample Processing Constant throughput: 400 T/H, optional ISE module with 400 T/H 90 sample positions, 80 reagent positions Dry Heating Thermostatic System Direct heating system enables faster heating and decreases pre-heating time Thermostatic system by dry heating keeps reaction solution in cuvettes at (37.0±0.2)℃ Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Bubble detection and probe-clot (clogging) detection Water-quality monitoring module (Optional) and Built-in degassing unit Advanced Optical system Optical system with diffraction grating and 16 wavelengths Glass reaction cuvettes with permanent use Intelligent Online Loading System Reagents can be loaded on-board during test Peltier system provides a longer maintenance period to reduce repair probability 8-step Warm Liquid Washing Whole probe stereo cleaning technology with cross-contamination rate<0.01% Anti-overflow function prevents liquid spillage Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1160 mm (L) * 790 mm (W) * 1140 mm (H) Gross Weight: 300 kg Sample Positions: 90 positions Reagent Positions: 80 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes Water Consumption: No more than 15 L purified water per hour Calibration: multi-point calibration curve with up to 7 points Dilution: automatic pre-dilution Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL
Key Features Sample In - Result Out Compact design &All-in-One system Fully automated nucleic acid extraction→PCR amplification→detection→analysis Quick Test Fastest turnaround time of 35 min from sample to result High Throughput Dual-module design, 12 test channels Multiple items could be detected simultaneously Room Temperature Transportation & Storage Advanced technology, freeze-dried reagent Convenient and cost- effective transportation Applicable Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Real-time PCR Time for the Result: 35 min Channels: 12 Module Number: 2 Sample Type: Nasopharyngeal swab, conjunctiva swab, anal swab, feces, whole blood, serum, oral and nasal secretion, genital tract swab, urinary tract swab, lesion exudate, cervical swab, sputum Thermal Cycling Technology: Peltier Dimensions: 424mm(L)*420 mm(W)*234 mm(H) Weight: 13 kg
Key Features Compact Design Bench top design Relatively lighter weight: 80 kg High Efficiency Throughput: up to 200 T/HFastest time for the first result: 10 min Dual-Tray Consumable Design 2 independent consumable trays, support replacement without pause 140 reaction cups per tray Smooth Reagent Management 24 reagent positions, support online loading PE film puncture technology, preventing reagents from evaporationEquipped with RFID, automatic identification of reagent information Application Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 200 T/H Fastest Time for the First Result: 10 min Reagent Positions: 24 Sample Positions: 50 Sample Type: Serum, plasma, urine, fingertip blood Application Scenarios: Laboratory, Clinics, Emergency, ICU, Wards Sampling Method: Steel needle STAT: Support STAT mode Sensing Functions: Liquid level detection, residual monitoring of reagent and sample, anti-collision Reaction Cups: 2 individuals consumble trays with 140 reaction cups each Reaction Temperature: 37℃±0.5℃ Magnetic Seperation & Washing: 3-step magnetic separation and 3-step washing Dimensions: 685 mm(L)*690 mm(W)*660 mm(H) Weight: 80 kg
Key Features Maximizing the potential of the laboratory Metis 600 modular system provides suitable solutions for immunofluorescence and hematology testing in low volume laboratories Standardization Improve laboratory efficiency through the highest level of automation Reliability Maximize reliable results with industry-leading instrument accuracy and service Rapid Accelerate turnaround time for high-volume sample testing and achieve new levels of rapid service Capacity The combination of Immunofluorescence and Hematology methodologies allows for a more comprehensive test items to be offered Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Technical Specifications BHA-5100 Automatic Hematology Analyzer Dimensions: 705 mm (L) x 670 mm (W) x 570 mm (H) Weight: 21 kg Methodology: Flow cytometry, impedance method, colorimetry Throughput: 60 T/H Test Items: 25 reportable parameters Quality Control Method: L-J quality control, X-B quality control Storage Capacity: > 100, 000 patient data Gem Hole: 50 μm Sample Volume: 15 μL Reagents: 1 diluent and 2 lysers Getein 1200 Immunofluorescence Quantitative Analyzer Dimensions: 570 mm (L) x 675 mm (W) x 574 mm (H) Weight: 43 kg Methodology: Quantitative immunofluorescence Sample Positions: 50, continuous sample loading Reagent Positions: 4 x 24/48 Throughput: 100 T/H Test Items: 59 items in 13 fields Storage Capacity: 100, 000 test results Dry System: ADP aspiration, no liquid path Automation: Automatic sample loading, mixing and decapping