Contact Getein
Search
13 results found for "clinical chemistry"
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-1000 Clinical Chemistry Analyzer
    Key Features CM-1000 (Standalone Version) Powerfully Compact  Smaller footprint without compromising speed 50 sample positions and support STAT samples Constant throughput: 1000 T/H, optional ISE module with 400 T/H Accurate Sampling System Internally and externally polished sampling probes, high precision Liquid volume tracking and level detection Reagent Module 103 reagent positions, simultaneous testing of up to (61 + 4 ISE) different items  270 quartz glass cuvettes, replaceable individually Advanced Track Unit 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority 8-step Warm Liquid Washing Double-row cleaning design 8-step washing, more thorough cleaning CM-1000 (SH 80 version) Intelligent Sample Processing Unit Constant throughput: 1000 T/H, optional ISE module with 400 T/H 190 sample positions with AI visual recognition for barcode scanning, sample type and tube identification, sample level and serum quality detection Accurate Sampling System Internally and externally polished sampling probes, high-precision Liquid volume tracking and level detection Reagent Module 103 reagent positions, simultaneous testing of up to (61 + 4 ISE) different items  270 quartz glass cuvettes, replaceable individually Advanced Track Unit 3 sample tracks: emergency loading, regular loading and sample returning Independent emergency track, emergency samples in priority 8-step Warm Liquid Washing Double-row cleaning design 8-step washing, more thorough cleaning Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions: 1100 mm (L) * 930 mm (W) * 1200 mm (H) Gross Weight: 400 kg Sample Positions: 190 positions  Reagent Positions: 103 positions Sample Types: Serum, plasma, whole blood, urine, and  cerebrospinal liquid samples Application Scenarios: Hospital Labs, Diagnostic Centers, Academic Research Institutes    Water Consumption: No more than 40 L purified water per hour Minimum Reaction Volume: 100μL Minimum Sampling Volume: 1.5μL  
  • Fully Automated Clinical Chemistry Analyzer
    Fully Automated Clinical Chemistry Analyzer
    CM-1600 Clinical Chemistry Analyzer
    Key Features CM-1600 (Standalone Version) Compact and Powerful   Same speed, smaller size with 50 sample positions Single analytical module only occupied 1 m²   Throughput can reach up to 1600 T/H, optional ISE module with 600 T/H Reagent Module 107 reagent positions, simultaneous testing of up to (63 + 3 ISE) different items  277 quartz glass cuvettes, replaceable individually Whole Blood Testing-HbA1c Direct testing supported, no pretreatment needed Fully automated in-machine hemolysis and detection Incubation and optical System Dry heating to maintain the reaction solution in the cuvette at 37.0 ℃  LED light source with a lifespan of 20,000 hours Washing Unit and Sample Probe 8-step cleaning with acid, alkaline, and warm water Equipped with probe clogging detection, horizontal anti-collision, vertical anti-collision Liquid level monitoring, and ultrasonic cleaning function Whole probe stereo cleaning technology with cross contamination rate 0.1 PPM CM-1600(SH 80 version) Advanced Sample Processing Throughput can reach up to 1600 T/H, optional ISE module with 600 T/H 190 sample positions with AI visual recognition for barcode scanning, sample type and tube identification, sample level and serum quality detection Reagent Module 107 reagent positions, simultaneous testing of up to (63 + 3 ISE) different items  277 quartz glass cuvettes, replaceable individually Whole Blood Testing-HbA1c Direct testing supported, no pretreatment needed Fully automated in-machine hemolysis and detection Incubation and optical System Dry heating to maintain the reaction solution in the cuvette at 37.0 ℃  LED light source with a lifespan of 20,000 hours Washing Unit and Sample Probe 8-step cleaning with acid, alkaline, and warm water Equipped with probe clogging detection, horizontal anti-collision, vertical anti-collision Liquid level monitoring, and ultrasonic cleaning function Whole probe stereo cleaning technology with cross contamination rate 0.1 PPM Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Latex immunoturbidimetry, immunoturbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Sample Positions: 50 /190 positions Reagent Positions: 107 positions Sample Types: Serum, plasma, whole blood, urine, and cerebrospinal liquid samples Water Consumption: No more than 70 L purified water per hour Minimum Reaction volume: 70 μL Minimum Sampling Volume: 1.0 μL  
  • Integrated Immunofluorescence and Hematology Modular System
    Integrated Immunofluorescence and Hematology Modular System
    Metis 7000 Modular System
    Key Features Automatic Utilizes an automated and streamlined workflow design to significantly reduce manual operational load Independent emergency track, striving for more treatment time Flexible Flexible expansion enables the combination and collaboration of 1-4 modules Optional choice for CS 700 system (Storage, retrieval and disposal) Compact Metis 7000 takes up only 2.5㎡ for two modules (without centrifuge or refrigeration) Only increasing 1.0 ㎡ for adding 1 more analytical module Intelligent Optional CS 700 refrigeration unit can realize: Automated temperature-controlled cold storage for test tubes, quality controls, and calibrators Positioning recognition and automated transfer of sample trays Automatic disposal of expired or waste samples Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu   Techinical Specifications MAGICL 8500 Immunochemistry Module Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 600 T/H Fastest Time of First Result: 12 min Using RFID to dynamically update reagent status Tilt-pour test cup loading, maximum capacity of 2000 units Dimensions: 1100 mm(L)×873 mm(W)×1232 mm(H) CM-1600 Clinical Chemistry Module Throughput: Constant speed of 1600 T/H; optional ISE module: 600 T/H Testing up to 66 items at the same time (ISE included)  Reagent Positions: 107  Sample needle ultrasonic washing Acid solution, alkaline solution, 8-step warm water washing Dimensions: 1100 mm(L)×873 mm(W)×1220 mm(H)  
  • Automatic Clinical Chemistry Analyzer
    Automatic Clinical Chemistry Analyzer
    BBA-300 Clinical Chemistry Analyzer
    Key Features Highly-efficient and Convenient Test  Constant throughput: 300 T/H Emergency samples in test priority at any time 45 samples positions, 2 emergency sample positions, 90 reagent positions Multifunctional and Precise Sample Probe Highly-polished probe Automatic inside and outside probe washing, reducing cross contamination Highly sensitive liquid level detection sensor, actively monitoring reagent volume Reaction Unit 120 cuvettes, can be replaced separately 5-step cuvette wash station, thorough cleaning Stirring Unit  Independent stirring paddle Imported Teflon coating technology, effectively preventing cross contamination Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Turbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions:1060 mm (L) * 660 mm (W) * 1230 mm (H) Gross Weight: 140 kg Sample Positions: 45 positions, 2 emergency positions  Reagent Positions: 90 positions Sample Types: Blood, urine, hydrothorax,  cerebrospinal liquid fluid Application Scenarios: Hospital labs, diagnostic centers, academic research institutes   Water Consumption: No more than 20 L purified water per hour Minimum Reaction Volume: 150μL Minimum Sampling Volume: 2μL  
  • Hand-held chemistry and immunofluorescence analyzer
    Hand-held chemistry and immunofluorescence analyzer
    Getein 208 Immunofluorescence Quantitative Analyzer
    Benefits where you need Instant Results Get results in 3-15 minutes Detection Performance Improved Reduced influence by temperature and improved detection accuracy Dry clinical chemistry and immunofluorescence Supporting multiple test items Combo test, highly efficient Reliable Accuracy Good correlation with CLIA method 32℃ constant test environment Convenient Easy to operate, user friendly interface Benefits where you need ICU Laboratory Emergency Clinic     Test Menu   Technical Specifications Dimensions: 160 mm × 80 mm × 24 mm (D×W×H)  Weight: 256 g Printer: Support for external Bluetooth thermal printer  Connectivity: USB/Bluetooth/WIFI Calibration: SD Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool  Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Chinese Cases Storage: Over 10,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
1 2

A total of 2 pages

Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Leave A Message

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service