Getein 1600 Immunofluorescence Quantitative Analyzer

Getein 1600 is a fully-automatic analyzer that has low failure rate and moderate measurement speed, which can meet multiple needs of emergency department and central laboratory.

  • Sample Type:

    Whole Blood/Serum/Plasma/Urine/Fingertip Blood
  • Methodology:

    Lateral Flow Chromatography (Immunofluorescence)
  • Sample Position:

    48 samples per run, 150 T/H
  • Dimensions:

    639 mm × 562 mm × 728 mm (D × W × H)
  • Weight:

    45 kg

Getein 1600

Immunofluorescence Quantitative Analyzer

 


 

Intended Use

Getein 1600 Immunofluorescence Quantitative Analyzer (hereinafter called Getein 1600) is a fully-automatic bench-top diagnostic analyzer. Combined together with bar-coded, ready-to-use strip cassettes, Getein 1600 is designed to deliver accurate testing results in minutes. In conjunction with dedicated test kits of Immunofluorescence, the instrument automates the detection and quantification of biomarkers for cardiovascular disease, renal disease, inflammation, fertility, diabetes mellitus, bone metabolism, tumor and thyroid in a biological sample.

 

Features

 Simple Operation 

Fully-automatic detection

Real-time monitoring of samples and consumables

Visualized reagent interface

 

 Intellectualized Software System 

Android system

User-friendly interface

Diversified test modes: random, batch, STAT

LIS/HIS connectivity

WIFI/4G data transmission

Network printer

 

 High Throughput 

48 samples per run

Continuous loading of different test items

Up to 150 tests/hour

 

 Accurate and Reliable Test Results 

Fully-automatic sample adding system

Disposable tips with filter elements, which avoid cross-contamination

Automatic calibration, dilution and sample loading

Fully-automatic quality control

 

 Traceability of Results 

Automatic barcode scanning of test items

Automatic recognition of reagents

 

 Easy for Standardized Management 

Fully-automatic sample loading and detection

Standard SOP documented

Meet the requirements of clinical laboratory standards

 

Operation

 

 

 

Specifications

 

Methodology

Lateral Flow Chromatography (Immunofluorescence)

Throughput

48 Samples/run; 150 Tests/hour

Sample

Whole Blood/Serum/Plasma/Urine/Fingertip Blood

Language

English/Chinese

Display

10.4-inch LCD Touch Screen; Resolution 1024*768

Weight

45 Kg

Printer

Internal Thermal Printer

Data Storage

Over 500,000 data

Dimensions

639 mm × 562 mm × 728 mm (D × W × H)

Application

Laboratory

 

 

Test Item

Cardiac Marker

hs-cTnI, cTnI, TnT, BNP, NT-proBNP, NT-proBNP/cTnI, CK-MB/cTnI, CK-MB/cTnI/Myo, CK-MB/hs-cTnI/Myo, CK-MB/cTnI, H-FABP, CK-MB/cTnI/H-FABP, CK-MB, hs-CRP

Coagulation Marker

D-Dimer

Inflammation

hs-CRP+CRP, PCT, PCT/CRP, SAA/CRP, SAA, IL-6

Renal Function

CysC, mAlb, NGAL, β2-MG

Diabetes

 HbA1c

Metabolic Marker

25-OH-VD

Thyroid Function

 TSH, T3, T4, fT3, fT4

Tumor Markers

tPSA, AFP, CEA, PGⅠ/PGⅡ

Reproduction/ Fertility

HCG+β, FSH, LH, PRL, AMH, Prog

Infectious Disease

Anti-HCV, Anti-TP, Anti-HIV, HBsAg, Anti-Hbs, 2019-nCoV IgM/IgG, SARS-CoV-2 Antigen, SARS-CoV-2 Neutralizing Antibody, Dengue NS1 Ag

Specific Protein and Rheumatism

RF, ASO, Anti-CCP

Others

Ferritin, Total IgE, Cortisol

Coming Soon: E2, T, Folate... 

 

 

 

 

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.
  • Immunofluorescence Quantitative Analyzer
Submit
Related Products
Leading 25-OH-VD Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading 25-OH-VD Fast Test Kit (Immunofluorescence Assay) Manufacturer
25-OH-VD Fast Test Kit (Immunofluorescence Assay)
>Getein 25-OH-VD Fast Test Kit is used to help understand the metabolic changes of bone.
Getein NGAL Quantitative POC Fast Test Kit Getein NGAL Quantitative POC Fast Test Kit
NGAL Fast Test Kit (Immunofluorescence Assay)
>Getein NGAL Fast Test Kit is used as an aid in the early diagnosis of acute kidney injury (AKI), risk classification and treatment monitoring.
COVID-19  Antigen Rapid Test Kit Colloidal Gold COVID-19  Antigen Rapid Test Kit Colloidal Gold
One Step Test for SARS-CoV-2 Antigen (Colloidal Gold)
>Getein One Step Test for SARS-CoV-2 Antigen (Colloidal Gold) is an aid in the diagnosis of patients with suspected SARS-CoV-2 infection in conjunction with clinical presentation and the results of other laboratory tests.
Leading fT3 Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading fT3 Fast Test Kit (Immunofluorescence Assay) Manufacturer
fT3 Fast Test Kit (Immunofluorescence Assay)
>fT3 Fast Test Kit is used as an aid in clinical routine diagnostics for the assessment of the thyroid status.
Dengue NS1 Ag Fast Test Kit Dengue NS1 Ag Fast Test Kit
Dengue NS1 Ag Fast Test Kit (lmmunofluorescence Assay)
>Getein Dengue NS1 Ag Fast Test Kit is used as an aid in the early clinical assessment of Dengue virus infection.  
Leading FluA/ FluB/ SARS-CoV-2 Real-time RT-PCR Kit Manufacturer Leading FluA/ FluB/ SARS-CoV-2 Real-time RT-PCR Kit Manufacturer
FluA/ FluB/ SARS-CoV-2 Real-time RT-PCR Kit
>Getein FluA/ FluB/ SARS-CoV-2 Real-time RT-PCR Kit is used to quickly identify whether a patient is infected with influenza A, influenza B or SARS-CoV-2, thereby effectively controlling viral infection.
CysC Quantitative POC Fast Test Kit CysC Quantitative POC Fast Test Kit
CysC Fast Test Kit (Immunofluorescence Assay
>Getein CysC Fast Test Kit is used as an aid in the assessment and evaluation of index of glomerular filtration rate, and has important application value in renal function, kidney damage and renal transplantation.    
Fully Automated Clinical Chemistry Analyzer Fully Automated Clinical Chemistry Analyzer
CM-800 Clinical Chemistry Analyzer
>CM-800 Clinical Chemistry Analyzer   Intended Use CM-800 is a fully automated analyzer intended for the quantitative analysis of chemical components in human serum, plasma, whole blood, urine, and cerebrospinal liquid samples.    Constant processing speed:800 T/h Reagent capacity: 114 Sample capacity: 137 Minimum sample volume: 1.5 μL Minimum reaction volume: 100 μL         Technical Specifications   Principle Latex Immunoturbidimetry, Immunoturbidimetry, Colorimetry Method Rate method, End point method, Fixed time method Throughput Constant speed 800T/h Optional ISE module 200T/h Sample Tray 137 sample positions (including patient samples, calibrators and controls)  Reagent Tray Reagent positions: 69 positions for outside track and 45 for inside track Minimum Reaction Volume 100μL Cuvette Quartz glass 165 cuvettes, individually replaceable Reaction Temperature Direct solid heating, (37±0.2) ℃ constant temperature control Instrument Water Consumption 20 L purified water per hour Dimensions 1640mm(L)× 940mm(W) × 1215mm(H) Weight 500 kg   Test Items       Liver Function TBA, AFU, ALT, AST, ALP, AMM, GGT, TP, GPDA, GLDH, ALB, TB, DB, PA, CHE, ADA, 5’-NT, LAP, MAO, CG, GR Renal Function CRE-E, Urea, UA, β2-MG, CYS-C, MALB, NAG, RBP, CSF Specific Protein and Rheumatism ASO, RF, CRP, fCRP, Fer, CCP, Hs-CRP, TRF, RBP, C3, C4, IgA, IgM, IgG Glycometabolism GLU-HK, GLU-OX, FMN, D3-H, HbA1c, GA, LAC, NEFA Blood Lipids and Cardiovascular TG, TCH, HDL-C, LDL-C, ApoA1, ApoB, ApoE, Lp(a), HCY, NEFA, ACE, Myo, Lp-PLA2 Pancreatitis LPS, AMY Venous Thromboembolism and Coagulation D-Dimer Trace Elements and Electrolytes Ca, Mg, P, CO2, Fe, Na, Cl, K, UIBC Myocardial Enzyme CK, CK-MB, CK-MB mass, LDH, HBDH, LDH1 Tumor SA, AFU, Fer, TRF Gastric Function PG Ⅰ, PG Ⅱ